3. Modify factory settings (not recommended)
In the "Settings" menu, use the "Factory" button
You will be prompted for a password.
settings without authorisation from the after-sales service will invalidate the warranty.
WARNING : This operation is used to assist servicing and future repairs.
The default settings should only be modified by an experienced profes-
sional person.
Unauthorized modification of factory settings may invalidate the
warranty.
The current value of each setting is displayed on the screen in the corresponding input boxes.
If you have been authorised to change a setting, select the setting and press the corresponding
input box.
The input screen appears. Enter the desired value and press "OK".
The chosen value must be available within the parameter's setting range (see "Factory settings
list", below), otherwise your choice will not be saved.
Factory settings list
H0
Cumulative heating run time set value
H1
Defrosting run sets maximum defrosting time
H2
Temperature to exit defrosting
H3
Temperature enter defrosting temperature 1
H4
Temperature enter defrosting temperature 2
H5
Temperature enter defrosting temperature 3
H6
Temperature enter defrosting temperature 4
H7
Temperature difference to enter defrosting 1
H8
Temperature difference to enter defrosting 2
H9
Temperature difference to enter defrosting 3
H10 Temperature difference to enter defrosting 4
H11
Temperature difference to enter defrosting 5
P0
The maximum compressor frequency when heating
P1
The minimum compressor frequency when heating
P2
The maximum compressor frequency when cooling
P3
The minimum compressor frequency when cooling
P4
The maximum opening of main EEV
P5
The minimum opening of main EEV
P24
Maximum set temperature when heating
P25
Minimum set temperature when heating
P26
Maximum set temperature when cooling
P27
Minimum set temperature when cooling
4. USE
OF CONTROL PANEL
Contact your after-sales service: changing the factory
Description
to access the factory settings interface.
Adjustment range
1~120 min
1~25 min
1°C~25°C
-20°C~20°C
-20°C~20°C
-20°C~20°C
-20°C~20°C
-20°C~20°C
-20°C~20°C
-20°C~20°C
-20°C~20°C
-20°C~20°C
30~100 Hz
30~60 Hz
30~100 Hz
30~60 Hz
80~480 P
45~480 P
30°C~60°C
5°C~30°C
15°C~30°C
5°C~15°C
Default V.
45min
12min
12°C
-1°C
-2°C
-4°C
-6°C
-7°C
-8°C
-8°C
-8°C
-8°C
100 Hz
30 Hz
70 Hz
30 Hz
480 P
60 P
40°C
15°C
35°C
7°C
EN