B
Product usage
Delay
Start/
Pause
Progress
indicator
Water Softener
The water softener must be set manually, using the water hardness dial.
The water softener is designed to remove minerals and salts from the water, which would
have a detrimental or adverse effect on the operation of the appliance.
The more minerals there are, the harder your water is.
The softener should be adjusted according to the hardness of the water in your area. Your
local Water Authority can advise you on the hardness of the water in your area.
Adjusting salt consumption
The dishwasher is designed to allow for adjustment in the amount of salt consumed based
on the hardness of the water used. This is intended to optimise and customise the level of
salt consumption.
Please follow the steps below for adjustment in salt consumption.
1.
Close the door, switch on the appliance;
2.
Within 60 seconds after the appliance was switched on press the Rapid button for more
than 5 seconds to enter the water softener setting mode.
3.
Press the Rapid button again to select the proper set according to your local environment,
the setting will change in the following sequence: H3 H4 H5 H6 H1 H2 H3;
4.
Without operation in 5 seconds or Press the Power button to end the setup model..
WATER HARDNESS
German
French
°dH
°fH
0 - 5
0 - 9
6 - 11
10 - 20
12 - 17
21 - 30
18 - 22
31 - 40
23 - 34
41 - 60
35 - 55
61 - 98
1°dH = 1.25 °Clarke = 1.78 °fH = 0.178mmol/l
The factory setting: H3
Every cycle with a regeneration operation consumes additional 2.0 litres of water, the energy
1)
consumption increases by 0.02 kWh and the program extents by 4 minutes.
Press this button to set the delayed hours for washing. You can
delay the start of washing up to 24 hours. One press on this button
delays the start of washing by one hour.
After completing program and function selection or delay time
setting, press this button to start or pause.
The progress light that corresponds to the current operation turns
on to show the progress of the cycle.
softner level
British
Mmol/l
°Clarke
0 - 6
0 - 0.94
7 - 14
1.0 - 2.0
15 - 21
2.1 - 3.0
22 - 28
3.1 - 4.0
29 - 42
4.1 - 6.0
43 - 69
6.1 - 9.8
21
Regeneration
Water
occurs every X
program sequence
H1
No regeneration
H2
10
H3
5
H4
3
H5
2
H6
1
EN
Salt
consumption
(gram/cycle)
1)
0
9
12
20
30
60

Publicidad