Minimum Cross-Sectional Area of
Power and Signal Cables (For reference)
Rated Current of
Appliance (A)
> 3 and
≤ 6
> 6 and
≤ 10
> 10 and
≤ 16
> 16 and
≤ 25
> 25 and ≤ 32
> 32 and ≤ 40
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal
cable, fuse, and switch needed is determined
by the maximum current of the unit. The
maximum current is indicated on the nameplate
located on the side panel of the unit. Refer to
this nameplate to choose the right cable, fuse,
or switch.
NOTE: In North America, please choose the
right cable size according to the Minimum
Circuit Ampacity indicated on the nameplate
of the unit.
b. Using wire strippers, strip the rubber
jacketfrom both ends of the signal cable
to reveal approximately 15cm (5.9") of
wire.
c. Strip the insulation from the ends.
d.
Using a wire crimper, crimp u-lugs on
the ends.
NOTE: When connecting the wires,
strictly follow the wiring diagram
found inside the electrical box cover.
2.
Remove the 2 screws fixed on the front panel
and side panel, then take it down to perform
wire connection(see the figure of outdoor
unit A).
Unscrew the electrical wiring cover and
remove it.(see the figure of outdoor unit B)
2 Screws
Outdoor Unit A
3.
Connect the u-lugs to the terminals
Match the wire colors/labels with the labels
on the terminal block. Firmly screw the u-lug
of each wire to its corresponding terminal.
Nominal Cross-Sectional
Area (mm°)
0.75
1
1.5
2.5
4
6
Cover
Screw
Outdoor Unit B
4. Clamp down the cable with the cable clamp.
5. Insulate unused wires with electrical tape.
Keep them away from any electrical or metal
parts.
6. Reinstall the cover of the electric control
box.
Australia models (MIDDLE PRESSURE)
Please prepare spanner and flat-blade
screwdriver before your installation work .
1. Remove two fixing screws, then remove the
front panel.
2. Use spanner and flat-blade screwdriver to
knock down two metal seals, then pick the
metal flakes out.
3. Connect the power cable and indoor &
outdoor connection cable. Clamp down the
cable with the cable clamp.
4. The wire groups shall be bound with cable ties
and fixed on the right side plate after they are
connected. The strong electric wire group and
weak electric wire group shall be led out
separately through the two knock down holes
on the bottom of the right side plate and
fastened with a locking connector as shown in
the figure below.