CLEANING THE AIR FILTER
A dirty air filter will reduce the compressor's performance and life. To avoid any
internal contamination of the pump, the filter should be cleaned frequently, and
replaced on a regular basis. Felt filters should be cleaned in warm, soapy water,
rinsed, and allowed to air dry before re-installation. Paper filter elements should
be replaced when dirty. Do not allow the filter elements to become filled with
dirt or paint. If the filter element becomes filled with paint, it should be replaced.
Direct exposure to dirty conditions or painting areas will void your warranty.
CHECKING THE RELIEF VALVE
Pull the relief valve daily to ensure that it is operating properly and to clear the
valve of any possible obstructions.
TESTING FOR LEAKS
Check that all connections are tight. A small leak in any of the hoses, outlet
tubes, or pipe connections will substantially reduce the performance of your air
compressor. If you suspect a leak, spray a small amount of soapy water around
the area of the suspected leak with a spray bottle. If bubbles appear, repair or
replace the faulty component. Do not over tighten any connections.
STORAGE
Before storing the compressor for a prolonged period, use an air blow gun to
clean all dust and debris from the compressor. Disconnect the power cord and
coil it up. Pull the pressure relief valve to release all pressure from the tank. Drain
all moisture from the tank. Clean the filter element and filter housing; replace the
element if necessary. Drain the oil from the pump crankcase and replace it with
new oil. Cover the entire unit to protect it from moisture and dust.
Perform the following maintenance at the intervals indicated below.
Inspect and clean air filter daily.
•
•
Check pump oil level daily.
Change pump oil after the first 10 hours of operation then every
•
100 hours.
NOTE: Use semi-synthetic, non-detergent air compressor oil.
•
Operate the pressure relief valves daily.
•
Check belt tension every 100 operating hours.
•
Drain tank daily.
•
Check and tighten all bolts every 100 operating hours.
NOTE: Do not over tighten bolts.
MAINTENANCE
SERVICE INTERVAL
17 - ENG