Motor Reset Switch; Operating Instructions; Break-In Of The Pump - Porter Cable PXCM601 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

before pressing the reset switch to restart the motor.
If the motor shuts down because of overload, wait 10–15 minutes so the motor
can cool down, then press (NEVER force) the reset switch (A) to restart the
motor (see Fig. 5).
NOTE: On stationary models not supplied with a power cord, the
electrical power must be wired into the pressure switch by a
Licensed Electrician.
A
BREAK-IN OF THE PUMP (Fig. 6 on page 12)
1.
Make sure the power is connected at the power panel.
2.
Check the oil level in the pump
(see "Checking the Oil" in the maintenance section).
3.
Open the drain valve (F).
may cause eye injury. Wear safety goggles when opening drain
valve.
when using an air compressor. Failure to do so may result in
hearing loss.
4.
Turn ON the main power disconnect switch. Turn the pressure switch to the
AUTO position (D). The motor should start. Allow the compressor to run for
30 minutes, to break in the internal parts.
NOTE: After about 30 minutes, if the unit does not operate properly,
SHUT DOWN IMMEDIATELY, and contact a qualified service center.
DO NOT return the unit to the store where it was purchased.
MOTOR RESET
Ensure that all guards and shrouds are in place

OPERATING INSTRUCTIONS

Escaping air and moisture can propel debris that
Risk to hearing. Always wear hearing protection
11 - ENG
Fig. 5

Publicidad

Tabla de contenido
loading