Descargar Imprimir esta página

Dometic GROUP WAECO AirConServiceCenter ASC5000 Instrucciones De Uso página 115

Estación de mantenimiento de aire acondicionado
Ocultar thumbs Ver también para WAECO AirConServiceCenter ASC5000:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

AirConServiceCenter
9.7
Meter readings
NOTE
I
The unit saves various meter readings. To access the total values – consec-
utively, since the unit was produced – enter the menu "Other selections" –
"Service" and enter the code "7783". Use the cursor keys
a particular entry.
These meter readings cannot be reset. To access the meter readings which
can be reset, enter the code "7782" under "Service". Also see "Changing the
vacuum pump oil" or "Changing the filter".
"From system" indicates how many grams of refrigerant have been ex-
tracted from air conditioning systems using the menu item "Short selec-
tion" or "Free selection" since the last reset (see date).
"from ext. vessels" indicates how many grams of refrigerant were added to
the unit using the menu item "Int. vessel filling" since the last reset (see
date).
"Filled in system" indicates how many grams of refrigerant have been filled
into air conditioning systems using the menu item "Short selection" or
"Free selection" since the last reset (see date).
"Vacuum time" indicates how long the vacuum pump has operated since
the last reset (see date).
"Service completed" displays the amount of service work performed using
the air conditioning service unit since the last reset (see date).
EN
From system
g.
STOP-EXIT
from ext. vessel
g.
STOP-EXIT
Filled in system
g.
STOP-EXIT
Vacuum time
min.
STOP-EXIT
Service completed:
Number
STOP-EXIT
Service tasks
or
07/09/10
1455
07/09/10
3395
07/09/10
1200
07/09/10
79
07/09/10
4
to select
115

Publicidad

loading

Este manual también es adecuado para:

8885200102