3. Adjust the Carrier Height
IMPORTANT! If the carrier has not been adjusted correctly, the bowl rim height may not be compliant with applicable
codes. If the bowl height is not correct, the finished wall will need to be removed to make the required adjustments.
NOTE: The minimum rim height is 15" (381 mm) when the finished floor is even with the bottom of the carrier legs. The
maximum rim height is 23" (584 mm) when the legs are fully raised. The carrier can be adjusted up to 8" (203 mm), with 6"
(152 mm) or less of adjustment sufficient in most installations.
Move the carrier into place in the stud pocket.
Temporarily secure the carrier in place so it will not fall.
Install the threaded rods several turns into the carrier.
Make a mark on the carrier 3-1/4" (83 mm) above the top of the threaded rod.
Measure from the finished floor to the mark "X" to determine the rim height of the bowl.
Loosen the nuts that secure the legs to the carrier.
NOTE: As the carrier is lowered, verify that the elbow aligns with the waste outlet pipe.
NOTE: If applicable, confirm that the gasket on the elbow stays correctly positioned as it enters the waste outlet pipe.
NOTE: If a cast iron elbow is required, make the connections following all applicable codes.
Adjust the carrier until the desired height is reached. Use a wrench to securely tighten the nuts to secure the legs in
place.
1247365-2-C
Nut
Leg
6
3-1/4"
(83 mm)
X
Threaded
Rods
Finished
Floor
Kohler Co.