7.4. ENVIRONMENTAL CONDITIONS
– Temperature: -20° C to + 60° C
– Relative humidity: 90% max.
– ATEX Zone (where provided ATEX equipment): see the following images, divided by model.
See p. 83
7.5. WORKING CYCLE
The machine is designed for 30 ' of continued use under conditions of nominal capacity.
Bypass operation (zero flow) may not exceed the maximum duration of 2 minutes.
8. PLATES AND INSCRIPTIONS
The tanks CTK and HIPPOTANK
tions for use:
[A] Identification plate CTK-HT + CE Marking
[B] Sticker with use warnings
[C] Rhomboid sticker 'flammable' with Class of portability and UN code corresponding to the transported material
[D] Environmental hazard sticker
[E]
Sticker with stackability indications
A 1202
For IBCs up to 450 litres only one label is sufficient.
For the IBC over 450 litres two labels on opposite sides are needed
[C]
Rhomboid sticker 'flammable' with Class of portability and UN code corresponding to the transported material
9. FEATURES
9.1. OVERALL DIMENSIONS
See p. 91.
9.2. LEGENDA
See p. 92.
MAN_CTK-HT_Rev.4 del 12.2023
come supplied with the required identification labels and graphic stickers that contain the main instruc-
®
25
EN