Chapter 5. Machine installation
5.3. Users
5.3.1. Loading the oil in the pump
If the pump has no oil, to load, fully use the provided bottle.
The oil loading operation must be carried out by trained and
authorised technical personnel.
To access inside the machine, remove the rear panel, using a screw
driver to remove the fixing screws.
Remove the cap to load oil (21) using the provided wrench and fill the
oil tank following the instructions indicated in the pump user manual
attached to the machine.
(20) Oil discharge plug
(21) Oil filling plug
(22) Oil inspection plug
5.3.2. Electrical connections
OBSERVE HEALTH AND SAFETY REGULATIONS!
If the machine is not equipped with the power supply plug, use a plug that is suitable for the
voltage and amperage values described by the rating plate and that can comply with the
rules in force in the installation country.
GROUNDING OF THE UNIT IS OBLIGATORY!
Before executing electrical connections, make sure the mains voltage matches the one on
the plate on machine rear and that the ground contact complies with the safety rules in
force. In case of doubts about the mains voltage, contact the local public supply Company.
Insert the plug on the cable from machine electrical cabinet in a mains power supply socket
that can be reached easily by the operator.
5.3.3. Gas connections
When carrying out packaging operations in modified atmospheres, use specific gas for food package in compliance with
the rules in force about food additives in the country where the machine is used.
The gas, which consists of a mixture of nitrogen, carbon dioxide and, more rarely, oxygen and other gases, is a "made to
measure" gaseous mixture, depending on the product to be packaged.
Never use gaseous mixtures in presence of oxygen in a percentage higher than the atmospheric
one (~ 19%).
Connect gas attachment, in case the machine is equipped with such a device, to the gas cylinder through the proper
tube (H) (see chapter 1.3.).
Pressure of gas plant has to be set on about 2 atm., bearing in mind the max. working pressure is 4 atm.
If the pressure is not correct, act on the knob of the pressure reducer (R) (see chapter 1.3.).
25