Chapter 6. Machine adjustment and setting up
6.3.4. Special programs Sr1, Sr2
Condition.
This program must be used in the following situations:
After the machine has been inactive for a long period.
After having sealed products with high humidity content (e.g. soups).
When noticing a decrease in performance of the machine (e.g.: time to reach vacuum is increased or it
is not reached at all).
This program lasts about 10 minutes and ensures complete cleaning of the pump, removing any liquid
emulsion that might be found in the oil. Do not seal any product while this program is running.
This program has no set variables.
To start the cycle:
Open the cover as soon as the display shows (Sr1).
Service.
This program should be used when machine malfunctioning occurs.
This program performs a complete cycle of pouch vacuum and sealing and has no settable variables.
Insert the food in the pouch,
Place the pouch inside the tank,
To start the cycle:
Open the cover as soon as the display shows (Sr2).
Should execution of this packaging cycle be faulty contact the technical support.
Stop button (8)
If this button is pressed during the vacuum stage, suction stops immediately and the machine proceeds by sealing
the pouch automatically. This function must be used for packing liquid and hot products, which may boil during the
vacuum cycle.
If it is pressed for a few seconds, with machine inoperative (when the display shows the program no.) the display
shows the software version of the electronic board.
Stand-by
After 20 minutes of inactivity the machine enters stand-by mode (condition that assures energy savings). During this
stage the Led is on (9).
Press button (4) to reactivate the machine.
6.4. Alarm messages
The electronic board detects a series of alarms that are indicated by the following messages, which appear on the
display (5):
E0
Eprom Error.
The electronic board is blocked. Contact the technical assistance service.
ER1
Data configuration error.
Contact the technical assistance service.
ER2
Calibration error.
Contact the technical assistance service.
ER3
Cycle counter error.
Contact the technical assistance service.
ER4
Faulty sealing relay.
Contact the technical assistance service.
ER5
Vacuum Timeout: overtime.
Ensure the set vacuum percentage is correct.
Ensure the cover gasket is not dirty or worn.
Make sure the cover closes correctly.
ER6
Vacuum gradient: increase is not reached.
Run the program Sr1 "Condition" to clean the pump from any oil emulsion.
ER7
Oil maintenance.
The machine has exceeded the number of cycles beyond which oil replacement is required.
Contact the technical assistance service.
close the cover with empty tank and press the Start button (3).