1. DESCRIZIONE DEI COMPONENTI
5. INSTALLATION
Default
Parameter
Description
value
C402
1
Not Used
C403
0
Not Used
C404
0
Not Used
C405
0
Not Used
C406
1
Not Used
C407
0
Not Used
C407
0
Not Used
C408
0
Not Used
C409
1
Not Used
C410
10
Not Used
Default
Parameter
Description
value
External temperature probe
-
-
alternative to that on board the machine
C420
0
Not Used
0-10V signal to compressor (connect to URC)
C421
4
C+ = terminal CN8-2 controller URC
C- = terminal CN8-1 terminal block URC
C422
0
Not Used
Remote On/Off
C423
0
Contact Closed = On
C424
0
Not Used
Remote Summer/Winter
C425
0
Closed contact = Winter
C426
0
Set point 2
C427
0
Not Used
C428
0
Not Used
C429
0
Not Used
PdC signal in alarm
C430
0
Phase L in presence of alarms
C431
0
Not Used
C432
0
Not Used
C433
0
Not Used
Connection of the RS-485 serial interface
Modbus connection protocol (RTU):
- Baudrate: 9600
-
-
- Frame Settings: E 8.1
- Address: 1
- Timeout: 1000
(*) Closing current, ground 0.5 mA (SELV: ultra low safety voltage)
SIGNAL CABLE (<24V): BUS-SCS cable consisting of 2 flexible conductors, with a cross-section of 0.50 mm
DATA TRANSMISSION CABLE (RS-485): 1 X 2 X AWG 24 FLEX S(FTP) LSZH RS485 MODBUS serial bus cables for Canbus and Modbus applications. Belden type 14S7KVZ or equivalent.
The shield must be grounded at one end of the cable only.
CONTROL CABLE (230 V):
Electric cable with section 1.5 mm
ATTENTION:
The system must be built in compliance with the relative project and in compliance with the regulations in force in the place of installation.
It is absolutely forbidden to pass signal and data transmission cables together with power cables with voltages> 50 V.
102
RECIPE 3 (C400=3)
CONFIGURABLE PARAMETERS
TERMINAL BLOCK PCB CONNECTION SPECIFICATIONS
2
.
Electrical cha-
Rif I/O
racteristics
Outdoor
NTC 10k at
A+ / A-
temp.
-
B+ / B-
100
C+ / C-
NTC 10k at 25°C
101
D+ / D-
Digital input (dry
102
E+ / E-
contact) *
103
F+ / F-
Digital input (dry
104
G+ / G-
contact) *
Digital input (dry
105
H+ / H-
contact) *
200
R1
201
T1
Output not live
202
M1 / M2
(dry contact)
Voltage output
203
P2
230V~ max 2A
Voltage output
204
W1
230V~ max 2A
205
U1
206
X+ / X-
Serial port
RS-485
- + G
2
, twisted with sheath and unshielded.
EN
EN
Cable
type
SIGNAL
25°C
-
-
SIGNAL
-
-
SIGNAL
-
-
SIGNAL
SIGNAL
-
-
-
-
SIGNAL
COMAND
COMAND
-
-
-
-
DATA
TRANSMIS-
RS-485
SION