Magnetrol ECLIPSE 706GWR Manual De Operación E Instalación página 34

Transmisor de nivel de radar de onda guiada de alto desempeño, 4ta generación
Ocultar thumbs Ver también para ECLIPSE 706GWR:
Tabla de contenido

Publicidad

2.6.5 Menú de Configuración del Modelo 706 — Ajustes de Dispositivo
Home Screen
Main Menu
Device Setup
Quick Start
Identity
Basic Config
I/O Config
Display Config
Advanced Config
Factory Config
Level Units:
Probe Mount:
Inches
NPT
Feet
BSP
Millimeters
Flange
Centimeters
NPT/Flushing
Meters
BSP/Flushing
Flange/Flushing
Probe Model:
Hygienic
7YD Coax HTHP
7YF Sngl Rod Std
Probe Coating:
7YG Sngl Rod Std
None (Bare)
7YJ Sngl Rod HTHP
PFA Coated
7YL Sngl Rod HP
7YM Sngl Rod HP
Probe Length:
7YN Sngl Rod HTHP
12 inches to 100 feet
7YP Coax HP
(30 cm to 30 m)
7YS Coax Steam
7YT Coax Std
Level Offset:
7Y1 Sngl Flex Std
-25 feet to +75 feet
7Y2 Sngl Flex Bulk
(-7.6 m to 22.9 m)
7Y3 Sngl Flex HP
7Y5 Twin Flex Bulk
Dielectric Range:
7Y6 Sngl Flx HTHP Cage
Below 1.7
7Y7 Twin Flex Clad
1.7 to 3.0
3.0 to 10
Above 10
Flow Setup:
34
Measurement Type:
Level Only
Interface and Level
Volume and Level
Flow
Flow Units:
Cubic Ft/Second
Cubic Ft/Minute
Cubic Ft/Hour
Gallons/Minute
Gallons/Hour
Mil Gallons/Day
Liters/Second
Liters/Minute
Liters/Hour
Cubic Meters/Hour
Flow Element:
Palmer-Bowlus Flume
Flume Channel Width:
4 inches
6 inches
8 inches
10 inches
12 inches
15 inches
18 inches
21 inches
24 inches
27 inches
30 inches
Parshall Flume
Flume Channel Width:
1 inch
2 inches
3 inches
6 inches
9 inches
12 inches
18 inches
24 inches
36 inches
48 inches
60 inches
72 inches
96 inches
120 inches
144 inches
57-606 Transmisor de Radar de Onda Guiada ECLIPSE Modelo 706
V-notch Weir
Maximum Flow
V-notch Weir Angle:
(calculated, read only)
22.5°
30°
Low Flow Cutoff:
45°
0 to 9999999 cubic
60°
ft/min
90°
120°
TOTALIZER SETUP:
Units:
Rect Weir with Ends
Cubic Feet
0 to 215.0 feet
Gallons
(0 to 65 m)
Mil Gallons
Liters
Rect Weir w/o Ends
Mil Liters
0 to 215.0 feet
Cubic Meters
(0 to 65 m)
NON-RESET
Cipolletti Weir
TOTALIZER:
0 to 215.0 feet
Multiplier:
(0 to 65 m)
1
10
Generic Equation
100
K
1,000
L
10,000
C
100,000
n
Value (read only)
Custom Table
RunTime (read only)
Custom Table Type:
Linear
RESETTABLE
Spline
TOTALIZER:
Mode:
CUSTOM TABLE
Disabled
VALUES:
Enabled
Up to 30 Pairs of
Head/Flow Data
Multiplier:
1
Reference Distance:
10
11.8 inches to 100 feet
100
(30 cm to 30 m)
1,000
10,000
Maximum Head
100,000
The Maximum Head
value can be revised
Value (read only)
depending on the value
RunTime (read only)
of the Reference
Distance, or for end user
Reset
preference.

Publicidad

Tabla de contenido
loading

Tabla de contenido