While the electrode is attached, the warning indicator lights up
trode holder and the ground is indicated in the same way. If the electrode cannot be detached,
remove the electrode holder and remove it manually using the appropriate protection and twee-
zers. Be careful as the electrode can be very hot.
DUTY CYCLE EXCESS PROTECTION OR THERMAL CONTROL DEVICE.
When there is protection by reaching the maximum duty cycle, or by internal heating of the machine,
the arc is extinguished and the LED
the welder cools down to continue its normal operation. Do not turn off the welder, allow the fans of
the equipment to cool the machine's power components until the LED light turns off. Only until this
moment can the machine be switched off or start welding again.
Note: to preserve the power components of the welding machine from heat accumulation, do not
disconnect it immediately after activation of the protection, as described above.
that identifies protection of the machine is illuminated, while
Work piece
14
. A short circuit between the elec-