BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
4
Installation and connection (continued)
4.4
Electrical Connection
Depending on the connection version the electrical
connection
is made by a fixed able or a plug connection.
The connection or pin assignments for the respective
version can be found in Tab. 4-5 and Tab. 4-6.
4.4.1
Connector S284/cable connection KA_ _
S284-
Cable
IO-Link with
pin
color
1Vpp realtime
signal
(BML SL1-ALZ_-
U_ZZ-AU1L-...)
1
WH
2
BN
Not used
3
GN
Not used
4
YE
C/Q/OUT1
5
GY
OUT2
6
PK
7
BU
8
RD
9
BK
10
VT
Not used
11
GY PK
12
RD BU
Not used
Shield
TR
Unassigned leads must not be connected.
1)
Connect to GND if not used.
2)
Tab. 4-5:
Pin assignment of connector S284/cable connection KA_ _
14
english
BiSS/SSI with
1Vpp realtime
signal
(BML SL1-ALZ1-
_0ZZ-ABA_-...)
+B(+cos)
−B (−cos)
1)
+Clk
1)
–Clk
–Data
+Data
L–
GNS
L+
VDD
−A (−sin)
+A (+sin)
1)
Preset
1)
Shield
If the sensor with processing electronics is
powered from a separate source, the grounds
of the sensor and processing circuitry must be
connected to each other.
Note the information on shielding and cable
routing on page 15.
Description
Cosine analog signal
Cosine analog signal, inverted
–
Clock signal BiSS C/SSI
–
Clock signal BiSS C/SSI
IO-Link data signal/Switching
output 1
Data signal BiSS C/SSI
Switching output 2
Data signal BiSS C/SSI
Sensor ground (0 V)
Supply voltage 18...30 V DC
Supply voltage 5 V DC or
10...30 V DC
Sinusoidal analog signal
Sinusoidal analog signal,
inverted
–
Digital input
2)
–
(Connector housing to) shield
Fig. 4-9:
Pin assignment of S284
plug (M12, 12-pin), view
from above on sensor
head)