BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
9
Analog interface sin/cos (1Vpp) (BML SL1-ALZ_-_ _ZZ-A...)
When operating IO-Link and the analog
interface at the same time noise may be
generated on the analog signal and result in a
worsening of the signal quality!
To operate both at the same time with no
degradation of signal quality use appropriate
filtering. For details refer to document Interfaces
for BML Magnetic Encoder (see Tab. 13-1 on
page 47).
With the analog sine and cosine signals +A (+sin),
−A (−sin), +B (+cos) and −B (−cos), the controller evaluates
the difference in signal amplitudes and, from the signals,
interpolates the precise position within a period. For a
movement over several periods, the controller also counts
the number of periods. The period is 2 mm.
For a detailed description of the analog
interface refer to the document Interfaces for
BML Magnetic Encoder (see Tab. 13-1 on
page 47).
www.balluff.com
english
39