Disposal Requirements; Unit Specifications; Technical Specifications; Electrical Specifications - Rotex RRRQ011AAV1 Manual De Instalación

Unidad exterior para bomba de calor de aire-agua
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 102
13. D
ISPOSAL REQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with relevant local and national
legislation.
14. U
NIT SPECIFICATIONS
Technical specifications
011
Casing material
Dimensions h x w x d
(mm)
1345 x 900 x 320
Weight
(kg)
120
Operation range
• heating (min./max)
(°C)
–20/20
• domestic hot water
(°C)
–20/35
(min./max)
Refrigerant oil
Daphne FVC68D
Piping connection
• liquid
(mm)
9.52
15.9
• gas
(mm)
Electrical specifications
011
V1
Phase
1N~
Frequency
(Hz)
Voltage range
• minimum
(V)
220/380
• maximum
(V)
240/415
Nominal running current
15.9
(A)
RRRQ011~016AAV1+Y1
Outdoor unit for air to water heat pump
4PW55782-1B
Model
014
016
Painted galvanised steel
1345 x 900 x 320
1345 x 900 x 320
120
120
–20/20
–20/20
–20/35
–20/35
Daphne FVC68D
Daphne FVC68D
9.52
9.52
15.9
15.9
Model
014
016
Y1
V1
Y1
V1
3N~
1N~
3N~
1N~
3N~
50
50
50
220/380
220/380
240/415
240/415
5.3
20.2
6.77
22.2
7.79
N
OTES
Y1
Installation manual
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rrrq014aav1Rrrq016aav1Rrrq011aay1Rrrq014aay1Rrrq016aay1

Tabla de contenido