Descargar Imprimir esta página

AEMC Instruments HIPOT H111 Manual De Instrucciones página 6

Probadores de seguridad eléctrica

Publicidad

Idiomas disponibles

Idiomas disponibles

FOR THE UNITED KINGDOM ONLY:
The wires in this lead are colored in accordance with the following code:
Green/Yellow:
Blue:
Brown:
As the colors of the wires in the power cord may not correspond with the
color markings identified in your plug/appliance, proceed as follows:
The Green & Yellow wire must be connected to the Earth terminal marked
with the letter E or by the earth symbol
Yellow.
The Blue wire must be connected to the terminal which is marked with the
letter N or colored Blue or Black.
The Brown wire must be connected to the terminal marked with the letter
L or P or colored Brown or Red.
If in doubt, consult the instructions provided with the equipment or contact
the supplier.
A suitably rated and approved HBC power line fuse should protect this
cable/appliance: refer to the rating information on the equipment and/or
user instructions for details. As a guide, cable of 0.75mm
tected by a 3A or 5A fuse. Larger conductors would normally require 13A
types, depending on the connection method used.
Use caution on any apparatus: potentially high voltages and currents
may be present and pose a shock hazard.
Safety is the responsibility of the user.
Always inspect the instrument and test cables prior to use.
Replace defective parts immediately with factory replacement
parts only.
4
Earth (Ground)
Neutral
Live (Phase)
Hipot Electrical Safety Testers Models H111 and H216
or colored Green or Green &
should be pro-
2

Publicidad

loading

Este manual también es adecuado para:

Hipot h1162129.602129.63