DISPLAYED ALARMS and WARNINGS:
If an ALARM or WARNING condition occurs, the relative code will be displayed.
The alarm and warning codes of the active functions displayed during machine operation are:
A1
CYCLE NOT COMPLETED
This alarm is displayed when the wash cycle was
interrupted by switching the machine off with the
Q1 botton.
The alarm is reset when the next wash cycle starts.
A2
ANOMALOUS OVERHEATING (BOILER)
This alarm is displayed when the temperature in the
boiler exceeds 105 °C or when at least one of the
temperature probes (tank/boiler) is short-circuited.
The alarm is reset when the temperature drops
below 102°C or when the probe is replaced.
A3
TEMPERATURE PROBE DISCONNECTED
This alarm is displayed when one of the tempera-
ture probes (boiler and/or tank) is disconnected or
interrupted.
The alarm is reset when the probe is reconnected
properly.
A4
FILL-UP TIMEOUT
This alarm is displayed when the tank does not fill
within 30 minutes or the BT boiler does not fill
within 8 minutes.
The alarm can be reset by turning the machine off
and on by pressing the START key.
A5
BT BOILER HEATING TIMEOUT DURING THE
INITIAL FILL-UP
This alarm is displayed when the boiler is not heated
within 30 minutes.
The alarm can be reset by turning the machine off
and on by pressing the START key.
H1
INSUFFICIENT RINSE WATER TEMPERATURE
This alarm is displayed if, during the wash cycle,
the rinse phase is carried out with the boiler at least
15°C lower than the set temperature.
The washing cycle is prolonged until the minimum
rinsing temperature is reached (max 8 minutes).
SELF-DIAGNOSTICS
H2
This alarm is displayed when the rinse phase is not
carried out correctly.
Reset the alarm by turning the machine off and on
from the START key.
H3
INSUFFICIENT WASH WATER TEMPERATURE
This alarm is displayed if, during the cycle, the wash
phase is carried out at least 10°C lower than the
set temperature
F1
DOOR OPEN WARNING
This warning is displayed when the door is open.
The warning remains displayed until the door is
closed again.
F2
TANK WATER FILL-UP
This warning is displayed when the machine is filling
water (only during the initial fill-up phase - only with
the starting temperature control active).
C1
This warning is displayed when the machine is run-
ning the SELF-WASHING cycle.
C2
This warning is displayed when the machine is run-
ning the DRAIN cycle.
FAILURE TO EMPTY THE TANK
DRAIN and SELF-WASHING CYCLE
DRAIN CYCLE