EN
from flammable liquids.
• Children should not have access to the unit. The optimum
storage temperature is 5˚ to 30˚C.
• Store the device in its original packaging.
• Only carry out cleaning and maintenance on an unloaded hoist.
CHECKING THE HYDRAULIC FLUID LEVEL
With long and frequent use of the lift, loss of hydraulic oil can occur.
This phenomenon is very rare and usually associated with an
elevator malfunction.
When the lift is working properly, the actuator oil tank should not
be inspected.
ATTENTION! When topping up the oil, the SAFETY VALVE must
not be unscrewed. The actuator system does not require
venting. Each raising and lowering of the lift arm automatically
removes any bubbles that may collect there from the actuator.
BEFORE USING THE JACK:
During shipment or handling, air in jack can become trapped in the
hydraulic system causing jack to malfunction. To release air from
the hydraulic system:
1. Turn release valve counter-clockwise with handle no more than
two full turns.
2. Remove oil fill plug.
3. Pump jack handle quickly in several full strokes.
4. Repeat above steps as needed. Remember to replace oil fill plug
INSTRUCTIONS FOR USING THE JACK:
TO RAISE:
1. With one end of jack handle, CLOSE RELEASE VALVE TIGHTLY by
turning it clockwise.
2. Place vehicle in PARK (in gear on standard transmissions) and
apply emergency brake.
3. Place jack under vehicle at proper lifting location. (Refer to ve-
hicle Owner's Manual). If needed, turn extension screw on jack
counter clockwise until it comes in contact with vehicle.
4. Insert jack handle into handle socket. PUMP THE HANDLE (oper-
ate it up and down) to lift vehicle to desired heights.
TO LOWER
1. Remove handle use small end to SLOWLY open release valve. (To
open turn SLOWLY In counter clockwise direction).
2. When vehicle fully lowered, remove jack. If extension screw has
been extended, turn it clockwise until it retracts enough to re-
move form vehicle
3. When jack has been removed from vehicle, close release valve
for storage.
GENERAL CARE OF YOUR JACK:
1. When jack is not in use lifting arm and pump lever should be in
full down position. This will protect precision machined surfaces
of the ram and the piston from corrosion.
2. Container is filled with 7fl.oz of hydraulic jack oil. For best results,
always use a good grade when adding or replacing oil. Avoid
mixing types of oil. Do not use brake fluid, alcohol, glycerine, de-
tergent motor oil, or dirty oil. In proper fluid can cause serious
internal. Damage to the jack, Esso brand (or equivalent) SAE 10
hydraulic oil is recommended in jacks with hydraulic system.
3. Keep your jack clean and well lubricated, as well as the outside
moving parts such as the lifting arm spindle, wheel bearings and
cross head pin.
4. Should any other parts be required, please refer to the sectional
drawings and quote appropriate part number, along with the se-
rial number of the jack when ordering.
5. ADDING OIL: with arm fully lowered and jack on level ground,
remove oil fil plug. Add oil if level is more than ½" below hole
replace cover plate.
6. REPLACING OIL: Oil should be replaced at least once every year. To
drain oil remove cover plate. Oil filler plug and release valve. Be VERY
CAREFUL to not allow dirt or any foreign matter into the system.
7. LUBRICATION: Put grease in fitting on base and lubricate lifting
arm spindle with oil, every 3 months.
8. RUST PREVENTION: Clean and wipe with an oily cloth, the piston
ram and pump piston every 3months or when signs of rust or
corrosion appear. When not in use, always leave the saddle and
pump piston in the completely down position.
2
TROUBLE SHOOTING:
1. Jack will not lower completely
Air in hydraulic system / Purge air from hydraulic system
Release valve stuck / Transfer weight load and clean valve
2. Jack will not lower weight
Release valve in open position / Close release valve tightly
3. Jack will not lift to full height
Oil level low / Fill to recommended level
Air in hydraulic system / Purge air from hydraulic system
4. Weak lifting
Air in hydraulic system / Purge air from hydraulic system
Dirty oil / Change oil Use SAE 5W
Release valve not completely closed / Close release valve tightly.
5. Jack will not lift load
Excessive weight / Decrease weight or change to higher capacity jack
Release valve In open position / Turn valve clockwise and tighten
Oil level low / Fill to recommended level
TECHNICAL DATA:
P/N: 01270, Model K0502, Model K0502:
Capacity 2000 kg
Lifting height 148 - 278 mm
Base 89 mm x 86 mm
Screw height 50 mm
P/N: 01271, Model K0505:
Capacity 5000 kg
Lifting height 195 - 380 mm
Base 102 mm x 104 mm
Screw height 60 mm
P/N: 02087, Model K0510:
Capacity 10 000 kg
Lifting height 200 - 385 mm
Base 125 x 121 mm
Screw height 60 mm
P/N: 01962, Model K0516:
Capacity 16 000 kg
Lifting height 225 - 425 mm
Base 143 x 138 mm
Screw height 60 mm
P/N: 01702, Model K0520:
Capacity 20 000 kg
Lifting height 235 - 440 mm
Base 156 x 157 mm
Screw height 60 mm
P/N: 02016, Model K0532:
Capacity 32 000 kg
Lifting height 255 - 405 mm
Base 170 x 185 mm
Screw height -
ENVIRONMENTAL PROTECTION
To prevent damage during transport, the appliance is packed.
This packaging is raw material that can be reused or recycled.
The appliance and its accessories consist of various materials,
such as metal and plastic. Please take damaged appliance
parts to a recycling collection point. For EU countries only It
is forbidden to dispose of the appliance as waste. According to the
European Directive 2012/19/EU on Waste Electrical and Electronic
Equipment (WEEE), unusable power tools must be collected
separately and taken to a recycling collection point. Recycling
as an alternative to the obligation to return the appliance: As an
alternative to the obligation to return the appliance at the end of its
useful life, the owner is obliged to participate in its proper disposal.
The end-of-life unit may also be taken to a recycling collection point,
which will dispose of it in accordance with the national regulations
concerning waste and the use of secondary raw materials.
DECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY AVAILABLE AT THE REGISTERED
OFFICE OF AMIO SP z o.o. ul. Handlowa 3, 41 - 807 Zabrze