EN-18
4.4 Setup Menu
Enter this menu to set scale parameters.
Reset:
Power on unit:
Zero Range:
Beeper Signal:
Beeper Key:
Accumulation:
End Setup:
Reset [reset]
Reset the Setup menu to factory defaults.
NO
= not reset
YES
= reset
Power on unit [pwWr.UN]
Set the unit of measure displayed at startup.
auto
= last unit in use when turned off
kg
= kilograms
g
= grams
lb
= pounds
oz
= ounces
lb:oz = pound ounces
Zero Range [ZErO]
Set the percentage of scale capacity that may be zeroed.
2%
= zero up to 2 percent of capacity
10%
= zero up to 10 percent of capacity
Auto Tare [A.tArE]
Set the automatic tare functionality.
OFF
= Automatic Tare is disabled
ON
= the first stable gross weight is tared.
ON-ACC = stable gross loads within the accept limits are tared (in Check
weighing mode).
Beeper Signal [Bp.sIG]
Set how the beeper responds in Check Weighing mode.
OFF
= the beeper is disabled
ACCEPT = the beeper will sound when the weight is within the Accept range.
UNDER
= the beeper will sound when the weight is below the Under setting.
OVER
= the beeper will sound when the weight is above the Over setting.
UNDER-
OVER
= the beeper will sound when the weight is below the Under setting
or above the Over setting.
no, yes
auto, kg, g, lb, oz, lb:oz
2%, 10%
off, accept, under, over, under-over
off, on
off, auto, manual
Exit menu
Ranger™ 2000 Series