Maintenance
Cleaning position
To make cleaning easier, the louvre can be brought into a special
position (depending on product type).
▶ Press the Mode and Swing keys simultaneously for one second when
the device is switched off.
▶ To exit the cleaning position: press and hold both keys again.
3.8.2
Changing over display and alarm buzzer (Mute Mode)
▶ To switch on or off the display at the indoor unit and the alarm buzzer:
press LED key.
▶ To display the current room temperature, press the LED key and hold
for 5 seconds.
▶ To display the set temperature: press and hold the LED key for
another 5 seconds.
3.8.3
Turbo cool/Turbo heat
When Turbo cool/Turbo heat is active, the indoor unit operates at
maximum power to heat or cool the room quickly.
▶ Turbo cool: switch on Cooling mode and press the Turbo key.
▶ Turbo heat: switch on heating mode and press the Turbo key.
Exiting the function:
▶ Press the Turbo key again.
3.8.4
Indirect airflow (Wind avoid me)
▶ To activate the indirect airflow: press
This function prevents a direct airflow on to persons.
The function is only available in cooling mode, dehumidification mode
and Fan Mode.
3.8.5
Keylock
The keys of the remote control can be locked with the keylock.
▶ To switch the keylock on/off: press the Clean and Turbo keys
simultaneously for 5 seconds.
The symbol
appears in the display when the keylock is active.
3.8.6
Advanced operating functions
▶ Press the Set key.
▶ Press the Set key or ., / keys to select the function.
–
= Follow Me function
–
= Wireless control function
▶ Confirm selection with the OK key.
Exiting the function:
▶ Repeat the above steps.
Follow me function (Follow Me)
The function activates the remote control at the current location in order
to measure the temperature at 3-- minute - intervals. The indoor unit is
now controlled with reference to these measurements.
The Follow Me function is only available in cooling mode, heating mode
and automatic mode.
The Follow Me function is only available for CL5000iU 4CC 35 E and
CL5000iU 4CC 53 E. Not available for any other models.
44
key.
Wireless control function
The purpose of this function is to establish a connection via WLAN.
To connect to WLAN an IP-Gateway (optional accessory) must be
installed.
4
Maintenance
CAUTION
Danger due to electric shock or moving parts
▶ Disconnect the power supply before carrying out any maintenance
work.
▶ Have any maintenance steps that are not listed here carried out by an
approved installer.
4.1
Replacing the batteries
You require 2 size AAA batteries. Using rechargeable batteries is not
recommended.
▶ Remove the battery cover ( Fig. 5).
▶ Insert new batteries, ensuring correct polarity.
▶ Reinstall the cover.
4.2
Cleaning the unit and the remote control
NOTICE
Damage to unit due to incorrect cleaning!
▶ Do not directly splash or pour water onto them.
▶ Do not use hot water, thinner, abrasive powders or strong solvents.
▶ Clean indoor unit and remote control by wiping them with a soft
cloth.
▶ Only have the outdoor unit cleaned by an approved contractor.
4.3
Cleaning the air filter
NOTICE
The air filter may deform in direct sunlight.
▶ Do not expose the air filter to direct sunlight.
Check the air filter every 2 weeks and clean if necessary. Always clean
before and after decommissioning for longer periods.
▶ Open the air inlet grille.
▶ Remove the air filter.
▶ Clean the air filter using a vacuum cleaner, or wash out with hot water
and a mild cleaning agent and dry in the shade.
If you clean the filter with water, the outer side of the air inlet grille should
be facing downwards away from the water jet, and when cleaning with
the vacuum cleaner it should be facing up towards the vacuum cleaner.
4.4
Decommissioning for longer periods
Before decommissioning for longer periods:
▶ Clean the air filter.
▶ Activate the self-cleaning of the indoor unit using the Clean button.
▶ After self-cleaning, switch on the fan mode until the indoor unit is dry.
▶ Turn off indoor unit and disconnect power supply.
▶ Take batteries out of the remote control.
▶ Protect the devices from dust.
Climate 5000i M – 6721849824 (2022/04)