8
INT
Connections
Fig. 8-1: Connection positions
Item
Name
X1
Ethernet
RJ45 10/100 BASE-T Con-
nector #1
X3
USB V2.0 Port #1
X4
USB V2.0 Port #2
X5
Serial RS232-1 Con-
nector #1
X7
Anybus CC – Fieldbus
X9
I/O Connector
X10
I/O Connector
*
When using tool Series 70:
≤3 m Tool Cable: can be used with a maximum of 25 m Extension Cable.
•
≤6 m Tool Cable: can be used with a maximum of 20 m Extension Cable.
•
•
Tool cables over 6 m must not be extended.
Apex Tool Group
X24
X3
X4
X7
X9
X10
X5
X1
Max. cable length
<m>
100
30
30
30
30
30
30
P2552HW | REV D l 2023-12
On/Off
X22
X42
X41
X21
X23
Fuse
Item
Name
X21
System Bus Connector
TSnet OUT
X22
System Bus Connector
TSnet IN
X23
Power supply connection
X24
*
Tool Connector NeoTek
Serie
30E(...)N(...)
50E(...)N(...)
70E(...)N(...)
X41
Emergency-Stop IN
X42
Emergency-Stop OUT
INT
Max. cable length
<m>
60
60
–
45
26
60
60
117