WARNING/CAUTIONS
& SAFETY
D D o o n n o o t t use Dopplers in the presence of
flammable gases such as anaesthetic
agents.
D D o o n n o o t t use in the sterile field unless
additional barrier precautions are taken.
D D o o N N o o t t : Immerse in any liquid,
(Except F F D D 1 1 probe)
use solvent cleaner,
use high temperature sterilising
processes (such as autoclaving),
use E-beam or gamma radiation
sterilisation.
This product contains sensitive electronics,
therefore, strong radio frequency fields could
possibly interfere with it. This will be
indicated by unusual sounds from the
loudspeaker. We recommend that the
source of interference is identified and
eliminated.
D D o o n n o o t t use on the eye.
If outputs 1 and 2 are used simultaneously,
the system should comply with EN60601-1-
1. Any equipment connected to outputs 1 or
2 should comply with EN60601-1, EN60950,
EN60065, EN60335 or EN61010.
D D o o n n o o t t dispose of batteries in fire as this can
cause them to explode.
D D o o n n o o t t attempt to recharge normal dry-cell
batteries. They may leak, cause a fire or
even explode.
Dopplex Dopplers are screening tools to aid
the healthcare professional and should not
be used in place of normal vascular or fetal
monitoring. If there is doubt as to vascularity
or fetal well-being after using the unit,
further investigations should be undertaken
immediately using alternative techniques.
We recommend that exposure to ultrasound
should be kept As Low As Reasonably
Achievable - (ALARA guidelines). This is
considered to be good practice and should
be observed at all times.
F F e e t t a a l l D D o o p p p p l l e e x x
The main unit is not waterproof and must not
be immersed. For underwater use where
contamination or cross-infection may occur,
additional barrier precautions must be taken.
M M e e a a n n s s A A t t t t e e n n t t i i o o n n c c o o n n s s u u l l t t t t h h i i s s
m
m a a n n u u a a l l . . R R e e f f e e r r t t o o s s a a f f e e t t y y s s e e c c t t i i o o n n . .
GENERAL OPERATION &
MAINTENANCE
Refer to diagram on inside front cover for
Doppler Measuring sites and Recommended
Probes.
D D u u r r i i n n g g U U s s e e
An automatic noise reduction feature operates
on low level signals to improve sound quality.
To replace battery see diagram.
A A f f t t e e r r U U s s e e
1.
Press and release the On/Off button.
If you forget to switch the unit off, it
will automatically shut-off after 3
minutes.
2.
Refer to the cleaning section before
storing or using the unit on another
patient.
3.
Store unit together with probe and
accessories in the soft carry case
provided.
The control unit and the body of the probe are
robust and require no special handling.
However, the probe tip is delicate and must be
handled with care.
C C l l e e a a n n i i n n g g
Remove excess gel before parking the probe.
Clean with a damp cloth impregnated with mild
detergent. Do not allow fluid to seep into either
unit.
For disinfection use a soft cloth with Sodium
Hypochlorite 1000ppm or alcohol.
Alcohol saturated swabs can be used on the
probe tip.
Please be sure to check your local control of
infection policies, or any equipment cleaning
procedures.
Phenolic, detergent based disinfectants
containing cationic surfactants, ammonia based
compounds, or antiseptic solutions such as
Steriscol or Hibiscrub should never be used on
any part of the system.
C C o o u u p p l l i i n n g g G G e e l l
Use water based ultrasound gel ONLY.
F F D D 1 1
Gel not required when probe used underwater.