5.2 Connection and electrical data

Speed:
Nominal widths DN:
Pipe joints
Permissible media temperature min/max
Ambient temperature min/max
Permissible humidity
Max. permissible working pressure
Insulation class
Protection
Electromagnetic Compatibility (EMC)
emitted interference according to
noise immunity according to
Sound pressure level
Flow media
Electrical connections
Power output
Motor temperature sensor
Speed control
Storage temperature
x Standard model
X Special model or optional equipment (additional charge)
When ordering spare parts, please specify all information on
the pump/motor rating plate.
Electrical data (power and current consumption), dimensions
and weights are given in the catalogue. The pumps are inten-
ded for use in TN or TT systems. Their use in IT systems (unearthed
systems) may be authorised after consultation with the manu-
facturer.
Flow media:
If water/glycol mixtures with a ratio of 10% or more glycol (or
flow media with a viscosity other than that of pure water) are
used, the increased power consumption of the pump is to be
taken into account. Only brand products with anti-corrosion
inhibitors should be used. The manufacturer's instructions must
be strictly adhered to.
The flow medium must be free of sediment.
x
If another medium is to be used, it must be cleared by
x
Salmson.

5.3 Scope of supply

Pump LRE / JRE
x
Installation and Operating Instructions
x

5.4 Accessories

Accessories must be ordered separately.
LRE and JRE: 3 consoles with mounting material for installati-
x
on on a foundation
DP-E: blind flange for repair purposes
x
IF module PLR for connection to PLR/interface converter. With
x
a DP-E, only one IF module is required in the master for this
purpose.
2900 rpm depending on power output
32,40; 50; 65; 80
Flange PN 10 drilled to EN 1092-2
- 10°C ... + 120°C
- 10°C to 40°C (50°C after separate release by the manufacturer)
0...95 %
10 bar
F
IP 55
EN 61800-3
EN 61800-3
< 71 dB(A)
Heating water according to VDI 2035
Cooling and cold water
Water/glycol mixture with up to 40% vol. glycol
Heat-conducting oil
Other media upon request
3 ~ 400 V ± 10%, 50 Hz
3 ~ 380 V + 15%, - 5 %; 60 Hz
short-circuit-proof according to EN 61800-5-1
PTC
integrated frequency converter
-20°C to +70°C
IF module LON for connection to the LONWORKS network.
x
With a JRE, only one IF module is required in the master for this
purpose.

6 DESCRIPTION OF PRODUCT AND ACCESSORIES

6.1 Pump and motor

All the pumps described here are single-stage low-pressure cir-
culation pumps in a compact design with coupled motor. The
pumps can be assembled directly as inline pumps in a well-
fastened pipeline or placed on a foundation base.
LRE: The pump housing is of an INLINE design, i.e. the suction
x
and discharge flanges are on a common centre line. All
pump housings are provided with pump feet. It is recommen-
ded that the pump be installed on a foundation base.
JRE: Two pumps are arranged in the same housing (double
x
pump). The pump housing is of an INLINE design. All pump
housings are provided with pump feet. It is recommended
that the pump be installed on a foundation base.
An electronic module attached to the motor housing regula-
tes the speed of the pump to a nominal value within a permis-
sible range of values. Depending on the control system invol-
ved, the differential pressure is subject to different criteria.
Regardless of the control system involved, the pump continual-
ly adapts itself to the varying power requirements of the units,
especially when being used in conjunction with thermostatic
valves or mixers.
The main benefits of electronic control are as follows:
it does not require overflow valves,
x
it saves energy,
x
it reduces noise caused by the flow.
x
it allows the pump to adapt to varying operating conditions
x
34
x
x
x
x
X
x
x
x
x