Descargar Imprimir esta página

SILKO ALI SNACK EFG6 Serie Instrucciones Para Instalación, Uso Y Mantenimiento página 43

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 57
• Do not use sharp objects which might scratch and damage
the surfaces.
COOKING TANKS
• Clean the tanks by bringing the water to the boil, with the
addition of grease remover detergent if necessary.
• Remove any limescale deposits with a proprietary limescale
remover.
FILTERS
reused, guarantees better cooking of the food. To clean the
a degreasing soap, rinse and dry When the procedure is con-
must be renewed
INSTRUCTIONS FOR MAINTENANCE
REMINDERS FOR THE MAINTENANCE TECHNICIAN
The manufacturer will not be liable for any damage or in-
jury resulting from failure to observe the following rules.
• Read this manual carefully. It provides important information
for safe installation, use and maintenance of the appliance.
• Disconnect the appliance electrical power supply, if present,
before proceeding with any operation.
authorized by the manufacturer, in compliance with current
safety standards and the instructions given in this manual.
detailed on the packaging and on the appliance data plate.
• The appliance must be installed in a well-ventilated room.
• Do not obstruct any air vents or drains present on the ap-
pliance.
• Do not tamper with appliance components.
CONVERSION TO A DIFFERENT TYPE OF GAS
See Chapter " Instructions for installation ".
COMMISSIONING
any maintenance operations, check appliance operation. In the
event of any malfunction, consult the next paragraph "Trou-
bleshooting".
GAS APPLIANCES
Switch on the appliance as directed in the instructions and re-
minders for use given in Chapter " INSTRUCTIONS FOR USE
" and check:
• the gas supply pressure ( see next Paragraph ).
fumes removal system.
CHECKING THE GAS SUPPLY PRESSURE
• To measure the gas supply pressure use a manometer with a
• Remove the control panel.
• Remove the screw from the pressure test point PP and con-
nect the manometer to the test point.
• Make the measurement with the appliance in operation.
ATTENTION ! If the gas supply pressure is not within the limits
( Min. - Max ) indicated in Table T2, cease operation of the ap-
pliance and contact the gas utility company.
• Disconnect the manometer and retighten the retaining screw
on the pressure connection.
ELECTRICAL APPLIANCES
Switch on the appliance as directed in the instructions and re-
minders for use given in Chapter " INSTRUCTIONS FOR USE
" and check:
• the current values of each phase.
• the correct operation of the heating elements.
15 TROUBLESHOOTING
GAS FRYERS
The pilot burner does not light
Possible causes:
• Blocked tubing or nozzle.
• Defective gas tap or valve.
• Igniter defective or not properly connected.
• Igniter or igniter wire defective.
• Defective safety thermostat
Pilot burner goes out during use
-
Possible causes:
• Defective gas tap or valve.
• Thermocouple incorrectly connected to gas tap or valve.
• Defective safety thermostat
The main burner does not light ( even though pilot is lit )
Possible causes:
• Blocked tubing or nozzle.
• Defective gas tap or valve.
• Defective burner ( gas outlet holes clogged ).
Heating cannot be adjusted
Possible causes:
• Defective gas valve.
ELECTRIC FRYERS
The appliance does not heat.
Possible causes:
• Temperature thermostat defective.
• Heating elements defective.
• Safety thermostat tripped.
Heating cannot be adjusted
Possible causes:
• Temperature thermostat defective.
9