Allows you to visually inspect the activation of the
commands and the safety protections: upon each
of their activations, the control unit briefly activates
the flashing and the Gate Open Light (terminal block
no. 16, SC).
The display indicates:
• the command activated, in fixed letters (on the
left-hand side, for a period of 5 seconds)
• in a flashing number, the safety protection
terminal block in a state of alarm (right part,
displayed as long as the safety protection is in a
state of alarm)
After 10 seconds of inactivity it will return to
commands and safety protections status mode.
To immediately exit test mode just press the TEST
button again
4

Installation

It is necessary to program the stroke to allow the
correct operation of the control panel.
WARNING! Before proceeding, make sure that:
• The leaf are in the fully closed position, or at least
• The
motor
has
with
parameter
C-
(
in simplified mode).
• The safety protections connected are at rest
and those not present are electrically bridged or
excluded by a special parameter
• If you are trying to access programming mode
but one of the safety protections is in a state of
alarm, you will not be able to do so. The display
changes to test mode and displays the input that
is in a state of alarm and which prevents you from
proceeding.
• If you are trying to access programming mode
but "man present" is enabled(par.
you will not be able to do so and the display will
AP PE
show
.
• The leaf are in the fully closed position, or at least
NOTE:
• Leaf 1 (terminal blocks 3, 4 and 5): it is the first
wing to open, this is also the wing on which the
pedestrian opening is performed.
• Leaf 2 (terminal blocks 6, 7 and 8): this is the first
wing to close.
• It is mandatory to have a gate stop also when
opening, or alternatively, use at least the limit
switch(also in this case it is a good idea to have
the gate stop, for additional safety).
26
been
correctly
selected
a1
in
extended
A7 01
• Programming is interrupted (with error message
AP PE
- The TEST button is pressed.
- One of the safety protections (photocells,
safety edges) is turned on.
- An abnormal operation condition was detected
(e.g.: excessive drop in voltage network).
In such an event you have to repeat the
programming of the stroke.
4.1

Stroke programming sequence

WARNING!
• If the limit switch are connected, the motion
stops when they are activated, otherwise it stops
on the gate stop.
• If you change the value of par.
extended mode (
it is necessary to repeat the programming.
To enter programming press the PROG button for 4
s.: the display will show
you can programme the stroke by pressing the
PROG button again, or by pressing the radio control
button enabled by the step-by-step function.
Premere PROG (o PP): programming is performed in
mode
a fully automatic way: wait for completion avoiding
crossing the ray of the photocells or activating other
safety devices (safety edges, stop).
The display shows the indication
motor 1 starts opening, after the phase shift time
established in par.
activated; when the wings both reach the fully open
position, stopping on the mechanical gate stop (or
on the limit switch in the case of a motor with an
articulated arm) the writing
the display for 2 seconds indicating that it is going to
close, then the indication
),
and the closing operation starts.
NOTE: the phase shift performed when closing is
that in memory (established by parameter
this value is set in the factory to 5 s; if both wings
require a greater value, for example, when the
stroke of wing 1 is less than that of wing 2, before
programming set the phase shift when closing high
enough to prevent the wings from overlapping.
NOTE: given that the programming is done at half
speed the phase shift times are automatically
doubled.
If the programming is completed properly, the
display returns to the status of the commands and
) in the following situations:
31
9-
A-
and
in simplified mode)
AP P-
AU tO
25
, motor 2 is also automatically
AU tO
AU tO
32
and/or
in
; at this point,
and
flashes on
stops flashing