Battery operation mode

If the battery kit is installed, in the absence of mains
voltage, the operation is guaranteed by 24Vdc backup
batteries that can be: 1200mAh if installed in the
housing of the charger or 4500mAh if installed in a
separate box. The 4500mAh ones are preferred in the
case of prolonged blackouts and when a remarkable
number of manoeuvres is to be carried out.
We recommend to check the efficiency of batteries
every six months.
For best performance it is recommended to
power all the external devices via the output SC
(Figure 7) after setting the parameter
A8 O4
(or
, if you also want the photo test).
The battery operation is shown on the display by the
Ba TT
message
and by the occasional activation
of the flashing light (saving consumption). At the
drop of the battery voltage the speed of the doors
decreases When the battery voltage drops below
a minimum value for its integrity, the commands
given to the control panel are no longer performed,
and the display shows
the function is restored when the mains voltage
parameter number
selectable values
A1 02
Motor model
01
piston BM20 BRUSHLESS
02
piston BR20 BRUSHLESS
03
articulated arms BR23 BRUSHLESS
04
underground motor BR21 BRUSHLESS
NOTE: parameter
The correct selection of the motor is critical for proper operation of the automation; an incorrect
setting of parameter
create occasional malfunctions which are difficult to fathom.
So pay a lot of attention to the value of this parameter; and because of its importance, when doing a
factory parameters restore this is the only parameter not to be changed.
28
A8 O3
BT L0
(Low battery);
A2 00
00
01
15
-
C-
in simplified mode
A1
may prevent operation but also in certain not particularly onerous cases,
is back or in case of possible recovery of battery
power, during the forced inactivity. Even if the phase
shifts are disabled, at every movement command
executed under backup power, a phase shift equal to
1.5" is performed. If the power failure occurs during
the travel, a stop of engine can be generated, with
automatic resume of motion after a stabilization
break (2").
4.6

Extended operation mode

N.B.: if you are only using the simplified mode the
value of the invisible parameters - for a control
unit leaving the factory, or after a reset of the
standard parameters - this is the one shown next to
the parameter, and is considered to be of greater
usefulness in installations.
WARNING! Depending on the selected mode,
some parameters may not be displayed, as they do
not relate to the installation.
The table for the extended mode parameters is
below. The standard production value is next to the
parameter number.
standard
production value
Parameter description
function associated with the value 00
function associated with values from 01 to 15