Commands And Safety Protections; Commands And Safety Protections Status Mode; Parameters Mode - Roger Technology B70/2DC Instrucciones Y Advertencias Para El Instalador

Centrale di comando 2 motori
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 74
In the simplified mode, standard production, for
example:
In extended mode, to be activated intentionally,
for example:
NOTE: in extended mode the parameter name is
highlighted by the presence of two illuminated
decimal points, and by the letter A for parameters
below 10, which are different from the first 10
parameters of simplified mode .
• MODALITA' STANDBY: makes the LED "POWER"
flash which indicates the presence of the power
supply voltage (decimal point of the furthest left
digit). It automatically switches to standby after
30 minutes of inactivity of the buttons around the
display
• TEST MODE the two digits on the left display
the name of the active command (for 5 seconds,
then it goes off), the two figures on the right
display, flashing, display the number of the safety
protection terminal block possibly in a state of
00
alarm (
if no safety protection is in a state
of alarm, then the control unit is enabled to run
commands; the only exception is when a limit
switch is activated, which is displayed, but is not
an obstacle to issuing a command). The safety
protection in a state of alarm will be displayed
until it returns to rest; if there are two safety
protections in a state of alarm, the second one
which is still in a state of alarm appears after the
first one has been resolved, before displaying the
safety protections with the highest priority and
then the other ones.
3.5.1

Commands and safety protections

status mode
The inputs are shown on the display in the following
way:
STATUS OF CONTROLS
AP
PED
PP
CH
ORO
POWER
FT = Photocells
ALWAYS ON
COS = safety edge
If the input is closed the corresponding segment
STATUS SAFETY PROTECTIONS
FT1
FT2
COS1
COS2
STOP
comes on. The segments corresponding to the
controls will normally be turned off (normally
open contacts), will be turned on upon receipt of
a command. The segments corresponding to the
safety protections installed must be turned on
(normally closed contacts); if they are turned off it
means that they are in a state of alarm.
SAFETY
PROTECTIONS
corresponding LED segment flashes
In the case of using articulated arms, therefore with
C-
parameter
set to value
A1
03
or
to value
in extended mode, and the limit
switch are provide during opening by parameter the
8-
parameter
to value
72
01
to value
in extended mode, the inputs ORO
and COS2 are displayed flashing (deactivated), and
inputs FCA1 and FCA2 are not shown. However, the
LEDs will flash if you do not enable the limit switch.
The meaning of the display segments becomes the
following:
STATUS OF CONTROLS
AP
PED
PP
CH
POWER
FCA = limit switch on opening
ALWAYS ON
FT = Photocells
COS = safety edge
3.5.2

Parameters mode

PARAMETER
UP
DOWN
PROG
UP
next parameter
DOWN
previous parameter
+
increases the parameter value by 1
-
decreases the parameter value by 1
PROG
programming the stroke (see par. 4.1)
TEST
enables test mode (see par. 3.5.4)
DEACTIVATED:
03
in simplified mode
01
in simplified mode, or
STATUS SAFETY PROTECTIONS
FT1
FT2
COS1
FCA2
STOP
VALUE
TEST
the
+
-
23