Descargar Imprimir esta página

LiftMaster LM50EVFF-1 Instrucciones De Montaje Y Manejo página 18

Accionamientos de puertas de garaje

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 45
15. The opener „runs" (audible turning of motor) but the carriage
does not move:
• The carriage is released from the opener.
• In a new installation: During the assembly of motor and rail, the pre-as-
sembled adapter sleeve between the motor shaft and the rail was not
installed. This sleeve is pre-assembled at factory, but can be removed.
Standing behind the opener it can be observed whether the gearwheel
turns in the rail or just the motor.
• In a new installation: The belt has come off from the gearwheel in the
rail. Standing behind the opener, you can see the gearwheel.
• After years of use: Is the release defective or continuously disen-
gaged?
• After years of use: The sleeve between rail and motor or the motor
control gear is defective.
16. The door releases by itself from the carriage and stops:
• An external release that has been installed during a power failure
should be checked whether it stretches and releases during the open-
ing of the door. Watch the mechanism and reset if necessary.
• The handle of the release mechanism should not get caught in other
items.
17. The running path cannot be programmed, is de-programmed
or is changing slowly:
• The programmed running path is too short. Programme a longer path
for testing purposes.
• A small plastic knob is factory-mounted on the chain that is running in
the rail. During the travel of the opener this little button must press the
small switch located on the drive head. If the path is too short or the
button was torn down by incorrect installation, it has to be fixed again.
If the small switch is not pressed, the programming of the opener is not
possible.
• A mechanical fault at the door due to deected joints or the chain
tension on the drive is too loose.
18. Description of LEDs
LED1
• Flashes briey: A radio signal is received. Once the remote control is
programmed it opens and closes the opener.
• Is constantly on for approx. 10 seconds: An additional remote can be
programmed or all remotes will be deleted.
LED2
• Is constantly on: as long as the opener runs.
• Flashes: opener is in programming mode, „OPEN" position has already
been programmed and opener is ready for position „CLOSED".
LED3
• Flashes: opener is in programming mode and ready for „OPEN"
position.
28
Specifications
Input voltage
Max. pulling force
Standby Power (door closed)
Motor type
Noise level
Drive Mechanism
Length of Travel
Opening speed, up to
Max. door weight
Max. door dimensions, height/width
Lamp
Door Linkage
Safety, Personal
Electronic
Electrical
220-240 VAC, 50/60 Hz
500 N
4.9 W
DC gearmotor permanent
lubrication
55dB
Belt
2498 mm (with rail 8323CR5)
100 mm/s
80 kg
2,3 m / 3,5 m
On when door starts, off 2-1/2
minutes after stop.
Adjustable door arm. Pull cord
trolley release
Push button and automatic stop
in down direction. Push button and
automatic stop in up direction.
Automatic force adjustment
Transformer overload protector
and low voltage push button
wiring.
Limit Device
Limit Adjustment
Soft-Start / Soft-Stop
Length (Overall)
Headroom Required
Hanging Weight
Memory Registers
Operating Frequency:
Transmitter Model TX4EVF
Transmitter Frequency
Transmitter Sending Power
Transmitter Battery
29
Door dimensions and -weight
One piece doors
max. width (mm)
max. height (mm)
max. weight (kg)
Sectional doors
max. width (mm)
max. height (mm)
max. weight (kg)
30
Service parts / Warranty
Your statutory rights are not affected by this manufacturer's warranty.
Please see www.liftmaster.eu for terms of warranty.
Always use LiftMaster accessories.
External products can cause malfunctions.
31
Accessories
(optional)
1.
TX4UNIF
4-channel universal remote control
2.
TX4EVS
4-channel remote control
3.
TX4UNI/S
4-channel universal remote control
4.
128EV
Wireless Wall Control 2-Channel
5.
780EV
Keypad
6.
EQL01EV
Quick release
7.
1702EV
Quick release
8.
75EV
Wired push button
9.
G770E
Photocells
10.
771EV
Photocells
11.
772EV
Photocells
12.
100034
Key switch (flush mount)
13.
100041
Key switch (surface mount)
32
Declaration of conformity
The manual consists of these operating instructions and the
declaration of conformity.
The radio equipment type TX4EVF is in compliance with Directive
2014/53/EU and for UK with Radio Equipment Regulation SI 2017 No.
1209. The full text of the EU declaration of conformity is available
at the following internet address: https://doc.chamberlain.de/
Mechanical RPM/Passpoint
detector
Electronic
Yes
3151 mm (with rail 8323CR5)
min. 35 mm
~ 10 kg
16
6-band 433MHz (433.30MHz,
433.92MHz, 434.54MHz)
868MHz (868.30MHz,
868.95MHz, 869.85MHz)
868MHz (868.30MHz,
868.95MHz, 869.85MHz)
<10 mW
3V CR2032
3500
2300
80
3500
2300
80
en 8

Publicidad

loading