Key Automation CT10324 Instrucciones Y Advertencias Para Su Instalación Y Uso página 16

Central para un motor 24 vdc para puerta de corredera o portón basculante

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
EN
5
6
7
8
9
10
11
12
13
14
1
15
5
16
17
18
16
0 = EDGE1 intervenes only during closing
with a short reversal
1 = EDGE1 intervenes during both closing
and opening with a short reversal
Attention: if the PAR input is used as EDGE2 then
must be 0
Edge test
0 = disabled
1 = enabled
Partial opening
Partial automation re-closing time
(0 = disabled)
Flashing light output setup
0 = Steady
1 = Flashing
Pre-flash behaviour (disabled if
0=before an opening or closing manoeuvre
1=before a closing manoeuvre
2=before an opening manoeuvre
Pre-flash time (0 = disabled)
Courtesy light configuration
0 = At the end of the manoeuvre turned on for time
1 = On if gate not closed + duration
2 = On if courtesy light time
Courtesy light duration time
Clearance. Used to stop before the completely open
position: it is useful to avoid mechanical stress during
opening.
!
WARNING
This parameter is only available for
swing doors.
If the door is closed and something tries to open it, the
door reacts by trying to close. Useful if a strong wind
could open the door.
0 = disable
1 = enable
!
WARNING
This parameter is not available for
swing doors.
Hold-to-run
0 = off
1 = on
0 = disabled
1 = open gate light ON/OFF
2 = proportional open gate light
- Slow flashing when the gate opens
- Quick flashing when the gate closes
- Steady light if the gate is open
- 2 flashes + pause with the gate stopped
(position other than closed)
3 = Electric lock
4 = Magnetic electric lock function
with active output when the gate/door is closed
(interface with external relay with 24 Vdc winding)
Service Interval Cycle Interval (0 = Off)
0
0
50
0
1
=0)
0
0
0
not expired
0
0
0
0
0
10
0
1
0
1
0
100
%
0
900
s
0
5
0
2
0
20
s
0
2
0
900
s
0
30
%
0
1
0
1
0
4
x 1000
0
200
cycles

Publicidad