4 - PRODUCT INSTALLATION
4.1 - Electrical connections
Before making the connections, ensure that the control unit is not powered up.
WARNING !
MOTOR CONNECTION
Power supply connection terminal board
M1 +
Power supply of motor M1 +
M1 -
Power supply of motor M1 -
V +
DO NOT USE
ENC
DO NOT USE
NEG
DO NOT USE
POWER SUPPLY CONNECTOR
L
Power supply live 230 Vac (120 Vac) 50-60 Hz
N
Power supply neutral 230 Vac (120 Vac) 50-60 Hz
Earth
L
N
M +
M -
POWER
SUPPLY
DIP SWITCH
Set on "ON" to disable inputs EDGE, PH1, PH2
This procedure avoids to bridge the terminal board inputs.
WARNING !
with the dip switch ON,
the safety devices are disabled.
EXAMPLE: With only 1 photocell
connected set EDGE and PH2 to ON
To disable, follow the procedure at paragraph 4.2
ON
STOP
PH2
PH1
OPEN CLOSE PAR
PH1
PH1
TX
RX
1
2
ON
OFF
ON
OFF
ANT
SHIELD
SBS
EN
7