Descargar Imprimir esta página

Key Automation CT10324 Instrucciones Y Advertencias Para Su Instalación Y Uso página 6

Central para un motor 24 vdc para puerta de corredera o portón basculante

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
EN
TECHNICAL SPECIFICATIONS
Power Supply
Maximum motor power
Maximum output current 24VAC
PH-POW maximum output current
Maximum FLASH output power
Maximum LED output power
Maximum power for the "IND/ELEC" output
Control unit fuse
Integrated radio receiver
Antenna
Number of saved transmitters
2.4 - List of cables required
The following table shows the cables necessary for connection of
the various devices in a typical system.
The cables must be suitable for the type of installation; for example,
ELECTRIC CABLE TECHNICAL SPECIFICATIONS
CONNECTION
Power supply line
Flashing light (FLASH)
Courtesy light (LED)
Antenna
Electric locking (IND/ELEC)
Photocells (transmitter)
Photocells (receiver)
Safety edge
Key switch
Motors power supply
3 - PRELIMINARY CHECKS
Before installing the product, perform the following checks and in-
spections:
check that the gate, the door or the barrier is suitable for automation;
the weight and size of the gate or door and the balance of the barrier
boom must be within the operating limits specified for the automa-
tion system in which the product is installed;
check that the gate or door has firm, effective mechanical safety
stops;
make sure that the product fixing zone is not subject to flooding;
high acidity or salinity or nearby heat sources might cause the pro-
duct to malfunction;
in case of extreme weather conditions (e.g. snow, ice, wide tempe-
rature variations or high temperatures), friction may increase, cau-
sing a corresponding rise in the force needed to operate the system;
the starting torque may therefore exceed that required in normal
6
CT10324
24 VAC (+10% -15%) 50/60 Hz
200 mA (24 VAC)
200 mA (24 VDC non-regulated)
15 W (24 VDC)
15 W (24 VDC)
5 W (24 VDC) / 15 VA (12 VDC)
1.6 AT (timed)
433.92 MHz OOK
wire or cable antenna RG58
we recommend a cable type H03VV-F for installation indoors or
H05RN-F/H07RN-F if installed outdoors.
CABLE
3 x 1,5 mm ²
3 x 2,5 mm ²
Connect the earth wire near the control unit
3 x 0,55 mm ²
cable RG58
2 x 1,5 mm ²
2 x 0,55 mm ²
4 x 0,55 mm ²
2 x 0,55 mm ²
4 x 0,55 mm ²
2 x 1,5 mm ²
conditions;
check that when operated by hand the gate, the door or the barrier
moves smoothly without any areas of greater friction or derailment
risk;
check that the gate, door or the barrier is well balanced and will the-
refore remain stationery when released in any position;
check that the electricity supply line to which the product is to be
connected is suitably earthed and protected by an overload and dif-
ferential safety breaker device;
the system power supply line must include a circuit breaker device
with a contact gap allowing complete disconnection in the condi-
tions specified by class III overvoltage;
ensure that all the material used for installation complies with the
relevant regulatory standards.
200 W
150
MAXIMUM PERMITTED LIMIT
< 20 m
> 20 m (50 m max)
20 m
10 m (recommended < 5 m)
10 m
20 m
20 m
20 m
20 m
10 m

Publicidad

loading