4.2 - Disabling the safety devices
EDGE
The control unit provides (default setting) for the installation of a safety edge connected to the EDGE inputs; in the event of a missing or
incorrect connection, the operation of the automation is inhibited. In a system where a safety edge is not to be installed, its use can be
disabled by setting the EDGE dip-switch to ON.
WARNING !
confirm the safety edge deactivation by pressing and holding the buttons
flashing.
PHOTO 2
The control unit provides (default setting) for the installation of one or more photocells connected to the PH2 input, in the event of a
missing or incorrect connection, the operation of the automation is inhibited. In a system where a PH2 is not to be installed, its use can
be disabled by setting the PH2 dip-switch to ON.
WARNING !
confirm the PH2 deactivation by pressing and holding the buttons
PHOTO 1
The control unit provides (default setting) for the installation of one or more photocells connected to the PH1 input, in the event of a
missing or incorrect connection, the operation of the automation is inhibited. In a system where a PH1 is not to be installed, its use can
be disabled by setting the PH1 dip-switch to ON.
WARNING !
confirm PH1 input deactivation by pressing the
PH1 LED stops flashing.
4.3 - Display during normal operation
The following table shows the messages displayed during normal operation of the automation.
MESSAGES
MEANING
The door travel has not been learned; perform the auto-learning procedure
Gate closed, control panel restarted
The gate is opening
The gate is closing
The gate was stopped during the opening manoeuvre
The gate was stopped during the closing manoeuvre
PH1 intervention (photocell 1)
PH2 intervention (photocell 2)
The automation is performing the realignment procedure
Gate open, automatic closing timer not active
The gate is performing a partial opening
The gate is stopped in the partially open position
The gate has reached the open position and automatic re-closing is active;the display alternately shows
The gate has been opened with the PAR command and the automatic re-closing timer from partial opening is
active; during the last ten seconds, the seconds remaining until re-closing are indicated
Auto-learning procedure blocked due to safety intervention or intentional stop
Auto-learning of leaf 1 opening travel
Auto-learning of leaf 1 closing travel
Personalised learning of the slowdown point during leaf 1 opening
Personalised learning of the slowdown point during leaf 1 closing
. During the last ten seconds, the seconds remaining until re-closing
and
and
until the PH2 LED stops flashing.
and
buttons simultaneously and holding them down until the
until the EDGE LED stops
EN
9