External S0 Port for ISDN Network Provider
Range
Terminators
External S2M Port for ISDN Network Provider
Connection type
Range
Terminator
PMP Port for Measurement Devices for Transparent Protocol Measurement
Guideline
Load resistance
Load damping
Power Supply Outlet Door
Output voltage
Door Terminal Port for Door Terminals
Interface
Relay Outputs for External Devices to be switched (e. g. Door Terminals)
Type of contact
Contact load capacity
Switch Inputs for Door Bell Buttons and Alarm/Announcement Contacts
Input voltage
Active state
Relay Output Second Ringer
Call voltage
COMmander 6000/R/RX - Instructions V11 11/2018
With typical phone or network cable (twisted-pair)
Max. 150 m for Point-to-Multipoint connection
Max. 1000 m for PTP connection
100 ohm, switchable; factory settings on
S
access as Point-to-Point connection, EURO-ISDN
2M
(DSS1)
Max. 100 m
120 ohm
Based on ITU-T G.772 and ITU-T G.703
432 ohm
20 dB
12 VDC, 100 mA per door terminal
FTZ 123 D12-0
Potential-free, 5 operating current contacts (NC), 1
operating and quiescent current contact (NC and NO)
Max. 30 V/1 A
Configurable: 0 V or 5-15 VAC/DC via the door bell button
(NC)
Contact is closed for more than 0.5 seconds
Approx. 45 V
, configurable: 25/50 Hz
eff
Important Information
49