Descargar Imprimir esta página

CEMO 60I Manual Del Usuario página 16

Sistema de depósito móvi compuesto por depósito de pe de una pared con bomba de manivela

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

GB
6. Maintenance and inspection
6.1
Safety measures
i
Important!
The operator must provide any protective clothing that may be required.
Who can carry out maintenance and inspection work?
» Normal maintenance work can be carried out by trained operating personnel.
6.2
Maintenance and inspection table
Interval
Assembly
As re-
Outside of filling station
quired
Container
Monthly
Piping system
Annually
Filter seal (diesel only)
100 l versions only: Tyre pressure of the wheels: 2 bar.
AdBlue
only: If there are any urea crystals clinging to the delivery nozzle or the station, you can remove
®
these easily and quickly with (lukewarm) water.
6.3
Troubleshooting
Fault
No output from pump
Reduced pump output
6.4
Cleaning the filter (diesel only)
N Hose connection
O Filter seal
16
Action
Remove any dirt
Visual check for damage
Check hoses for cracks and porosity, check fittings for leaks
(replace defective parts)
Clean (see section 6.4)
Possible cause
Trolley/caddy empty
Delivery line ball valve closed
(diesel only)
Hoses are blocked or kinked
Air in the system
Filter seal clogged (diesel
only)
13
14
Solution
Fill trolley/caddy
Open ball valve
Check hoses
Vent the system, see section 4. Initial
setup
Clean (see section 6.4)
1. Unscrew hose connection N
2. Remove, clean and reinsert filter seal O
3. Mount hose connection N