50
MENU4
Auto
close
time
setting
AUTO CLOSE Time &Condition Setting
- Press and hold SET button for
about 6 seconds to enter main
menu until "0.-" appears on the
display then release the button.
- Press UP till "4.-" appears on the
display.
- Press SET enter into the AUTO
CLOSE time and condition setting
- Press SET again to enter, the
digital displays
Adjust the stalls from
by buttons +/-, 5 seconds per stall
AUTO CLOSE time calculation
method is 5S*N, N=01—99.
The maximum AUTO CLOSE time is
495S, press the SET button to store
the required AUTO CLOSE time
setting, then
the digital tube displays
(default) which means that it has
entered the AUTO CLOSE condi-
tion setting,
Adjust by buttons +/- from
.
Select the corresponding function,
press the SET button to save and
exit the menu setting.
Remark:
The AUTO CLOSE function is turned
on, which means the door is
controlled by the AUTO CLOSE
button on the control box.
Condition
the door is opened to the open
limit position, the AUTO CLOSE
function is e ective and starts
timing.
(default)
to
or
or
means: Only after
Opening your life
1 19