XH06-2 Relay output
module function setting
Press and hold SET button for
about 6 seconds to enter main
menu until "0.-" appears on the
display then release the button.
- Press "+" till "6.-" appears on the
display.
- Press SET then appears "6.0" on
the display
- Press "+" till "6.8" appears on the
display.
- Press SET enter into Safety device
port function selection
Reach the open limit position, relay
closed
Reach the close limit position, relay
closed
Reach the partial open limit
position, relay closed
Before the door drive running, the
relay is closed rst (1-7 seconds
time adjustable)
Press SET to con rm and directly
enter the time setting. Adjust the
stalls from
to
by buttons
+/-.
default : Represents 3 seconds.
Relay always closed during the
door drive running. After the door
drive stops, relay will be disconnec-
ted after 1-10 minutes delay.
(Adjustable time, similar to cour-
tesy light OFF DELAY function).
Press SET to con rm and directly
enter the time setting. Adjust the
stalls from
to
buttons +/-. A=10.
means : 10 minutes ;
default : Represents 3 minutes