50
Safety device port
function selection
The relay is closed during door
drive operation.
When the door drive running, the
relay ashes at a frequency of 1HZ
(externally extended warning light
function)
Relay no action
Remark
default.
The customer can set the function
according to the speci c use
situation and choose the appro-
priate function with the normally
open (NO) and normally closed
(NC) function of the relay.
Press and hold SET button for
about 6 seconds to enter main
menu until "0.-" appears on the
display then release the button.
- Press "+" till "6.-" appears on the
display.
- Press SET then appears "6.0" on
the display
- Press "+" till "6.8" appears on the
display.
- Press SET enter into Safety device
port function selection
Use optical edge sensor kit. Or 8.2K
resistor in series with the rope
switch.
Use three-wire infrared photo
eyes.
8.2K resistor is used to short-circuit
Remark
the safety port by default.
Opening your life