TX/RX Function module description (optional)
1) The external decoding module uses the standard HCS301 format open code, the frequency 433MHZ/868MHZ is optional,
2) Transmitter 4 button design ; Transmitter key value 1, 8, 2, 4
3) The transmitter module and control box use USB standard interface to connect
4) Short press the LEARN button on the module, the LED will light up, press the remote control to learn the code. Long press
the learn button on the module for 6 seconds, LED will ash 5secondsquickly to clear the code
5) The default maximum number of transmitter storage is 50codes, and if 50 codes is already learned, the 51stcodewill auto-
matically cover the 1stcode.
6) Transmitter module function:
a) Standard function: Single key cycle
b) Ignore the key value function, all keys are valid: OPEN-STOP-CLOSE command order each cycle. As long as learning a key,
the others are valid
c) Multiple function key 1:
- 1st button execute OPEN-STOP-CLOSE command order each cycle.
- 2nd button execute PARTIAL OPEN command order.
- 3rd button execute courtesy light ON/OFF command order.
- 4th button execute remote LOCK command order.
d) Multiple function key 2:
- 1st button execute OPEN the door command order.
- 2nd button execute STOP command order.
- 3rd button execute CLOSE the door command order.
- 4th button execute remote LOCK command order.
e) Multiple function key 3:
- 1st button execute OPEN the door command order ;
- 2nd button execute STOP command order;
- 3rd button execute CLOSE the door command order;
- 4th button execute "CF" command order; ("CF"command order means press the 4th button, the door will OPEN directly
without STOP action, execute the REVERSE action during door closing)