Operating modes
Description
Automatic mode:
Operating mode for normal operation.
Time-dependent operation
Manual cleaning
Proceed as follows
Press
for 3 s
LED (6) is lit
The display indicates CL
To cancel the process: Press the button
again
Settings in the menus
Settings can only be made in the menus when the control system is switched on. (→ Switching
ON/OFF)
CL: Cleaning time "Cleaning"
Setting the cleaning time changes the duration of the cleaning cycle. Extend the cleaning time if the
dirt is not completely carried away by the water. This may become necessary if, for instance, very
long drain pipes or drain pipes with many bends were installed or there is a particularly large amount
of sticky dirt (e.g. during spawning).
Please take into consideration that an extended cleaning time leads to increased water consumption.
The default setting of 10 s is normally sufficient (corresponds to approx. a
Proceed as follows
1.
Press
several times until Cl appears
on the display.
2.
Press
for 5 s until the time is indi-
cated on the display.
3.
Press
several times to change the
value.
To change the value quickly: Hold down
the button
Information
By default the display indicates the water temperature.
A cleaning cycle is automatically started if the level detection device
signals an excessive deviation in the water level.
The level exceeds a specific water level.
After 20 automatic cleaning cycles, a cleaning cycle with extended
cleaning time is performed.
In addition to the automatic cleaning cycle (depending on the water
level in the drum filter), a time-controlled cleaning cycle can be exe-
cuted. (→ In: Time-dependent cleaning "Interval")
The duration of the cleaning cycle corresponds to the time set in the
cleaning time "Cleaning" menu. (→ CL: Cleaning time "Cleaning")
Information
The drum motor is stopped for safety reasons if the filter cover is
lifted. The rinsing pump can still be manually started to check the
function of the nozzles.
Each active cleaning cycle (automatic, time-dependent or manual)
can be stopped by pressing the button.
Information
To cancel and exit the menu: Either wait for 10 s or press
.
To cancel and exit the menu: Either wait for 5 s or press
.
Adjustable range: 10 – 30 s
Increment: 1 s
The number can only be changed upwards. Once the value 30 is
reached, the display returns to 10.
Saving the set value: Wait for 5 s until you automatically exit the
menu.
Cancel without saving and exit the menu: Press
7
/
drum rotation).
8
or
or