System messages
The 4-digit system message is indicated in the display by two groups of two digits in succession.
Er11
Container cover raised
Possible cause
Container cover raised
Container cover incorrectly fitted
Signal box not connected
Functions that are still available:
Manual cleaning (only nozzles, filter drum not rotating)
Resetting message
Automatic when the container cover is fitted.
Er22
Water temperature >53.6 °F (12 °C) AND the last automatic cleaning process was carried out more than 24
hours ago
A Possible cause
Screen elements leaking
Check screen elements, replace if necessary
Level detection device stuck or defective
Level detection device set incorrectly
Functions that are still available:
Manual cleaning
Automatic mode
Time-dependent cleaning
Resetting message
Press
Automatic as soon as the level detection device is triggered.
B Possible cause
24 hour check mode is active and time-dependent
cleaning is deactivated.
Functions that are still available:
Manual cleaning
Automatic mode
Resetting message
Automatic
key for 5 s
Remedy
Refit the container cover
Turn the container cover around so that the magnets
in the container cover are located over the signal box.
Connect the signal box to the control system.
Remedy
Check screen elements, replace if necessary
Check the drum seal
Clean the level detection device to ensure that the
mechanism moves freely, replace if necessary.
Adjust the level detection device
Remedy
Time-dependent cleaning is automatically activated
by floats after check mode.