E7: Pump status detection
(deactivated for pump-fed system)
The pump status detection signals via the system message Er88 if the pump is operating correctly.
The status detection is deactivated in the default setting.
If the system message ER77 or ER88 is displayed, it is necessary to change the status detection manu-
ally.
Proceed as follows
1.
Press
several times until E7 appears
on the display.
2.
Keep
pressed for 5 s until the value 0
or 1 is indicated in the display.
3.
Press
to change the value.
Reading out the number of cleaning cycles
Cleaning cycles in 24 hours
Proceed as follows
Press
and
for 5 s.
Information
To cancel and exit the menu: Either wait for 10 s or press
.
To cancel and exit the menu: Either wait for 5 s or press
.
Adjustable range: 0 or 1
0: The pump status detection is deactivated.
1: The pump status detection is activated.
Important: Ensure that the value is set to 0 (status detection deac-
tivated).
Cancel without saving and exit the menu: Press
Information
The sum of the automatic and time-dependent cleaning cycles is saved.
The 4-digit value is displayed in groups of two digits that appear in suc-
cession on the display.
Example:
01-17: Represents 117 cleaning cycles
The number is repeated five times after an extended pause to make it
easier to read:
01-17---01-17---01-17---01-17---01-17
Note:
If the mains voltage is switched off, the counter is reset to 0.
Note:
Due to the self-test of the filter system very different values may be
displayed. The self-test monitors the automatic cleaning process. The
test is carried out continuously in a 2 × 24 hour cycle. The test is only
active from a water temperature of >53.6 °F.
First 24 hour cycle
− If at least one automatic cleaning process is detected, the cycle is
repeated after the cleaning process has finished.
− If no automatic cleaning process is detected, the second 24 hour
cycle starts once the first has finished.
Second 24 hour cycle
− The time-dependent cleaning cycle is deactivated. This reduces
the number of cleaning cycles.
− If at least one automatic cleaning process is detected, the first 24
hour cycle starts again once the cycle has finished.
− If no automatic cleaning process is detected, the system message
Er22 is triggered at the end of the cycle. The time-dependent
cleaning cycle starts again. If an automatic cleaning process is
then detected, the first 24 hour cycle starts again. The system
message Er22 is automatically reset.
or
or
or
.