Operation
1. In the normal operation adjustment process of the induction cooktop, the maximum power of the two
zones on the same side should not exceed 3700W. If the calculated total power exceeds 3700W during
the adjustment process, reduce the power without operating on the same side to ensure that the actual
power is the user's desired power and the total power does not exceed 3700W.
2. There are two modes in the product, power saving mode (external mode) and conventional mode (in-
ternal cycle mode). In energy saving mode there is no boost power, and in conventional mode there are
two boost powers, this is the conventional mode by default; In standby mode, press and hold the fan key
and child lock key 2S to enter the status change mode. At this point, press the fan key to switch modes. 0
indicates normal mode and 1 indicates power saving mode.
3. Once all parts of the board are off for 5 minutes, the power supply to the board will be automatically
disconnected. At this time, the functions related to the cooking zones will not work, the operation indica-
tor light and display will go out, and the cooking zones can be reset by briefly pressing the cooking zones
confirmation key or by using the power key to restart the unit.
Plate power distribution
Power level
Power (W)
Plate power distribution with linked zones
Power level
Power (W)
Hood power distribution
Power level
Suction
power(m3/h)
Operating time
(min)
0
1
2
0
100
180
0
1
2
0
100
180
0
1
2
0
290
380
Long duration time
3
4
5
280
380
500
3
4
5
280
380
500
3
4
5
410
440
470
61
6
7
8
800
1000
2200
6
7
8
800
1000
2200
6
7
8
500
540
580
8
English
b
3700
b
3700
b
650
5