IMPORTANT
1) READ AND UNDERSTAND INSTRUCTIONS BEFORE INSTALLING OR USING HEATER.
2) RETAIN INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE.
3) CHECK LOCAL AUTHORITY & BUILDING CODES FOR INSTALLATION REQUIREMENTS.
For the Operate WiFi mode
The WiFi mode needs to purchase optional parts that are not standard installation.
Please contact to your dealer for purchase the following option parts.
Use only genuine TOYOYOMI parts for your heater. Use of unauthorized,generic or other brands parts can
severely reduce performance and safety,and will void factory warranty.
Only your dealer can install the WiFi module in your heater. DO NOT install the WiFi module to heater by yourself.
SECTION A:
SPECIFICATIONS
Model:
Heater Efficiency:
Heat Rating:
Fuel Consumption:
Fuel System:
Fuel Type:
Dimensions (W × H × D):
Weight:
Vent Pipe Hole:
Maximum Length of Vent Pipe System:
Electrical Rating:
Frequency band(s) in which the radio equipment operates:
Wireless LAN:
(1)
Heat and vaporized water are produced by fuel combustion. Heat rating does not account for heat loss due to
condensation of water vapor.
(2)
External tank to be purchased separately. (Consult your supplier for options.)
(3)
It is excluded from CE marking.
(4)
The WiFi mode needs to purchase optional parts that are not standard installation.
Your heater is equipped with the following safety features. Please familiar-
ize yourself with these features. When your heater is extinguished due to a
safety machanism, be sure to identify the problem correctly.
1. Flame Sensor
Heater will automatically stop all operations if ignition fails or if flame fails during combustion, in order to prevent
fuel overflow. Error code will be displayed on the operation panel.
2. Fuel Strainer
Special strainer catches dirt or impurities present in the fuel before it is sent to the burner.
3. Overheat Protector
Automatically stops all operations if the heater's inside cabinet reaches abnormally high temperature due to mo-
tor malfunction or abnormal combustion, in order to prevent fire.
4. Power Failure Recovery System
If power fails during heater operation, heater will automatically reignite and maintain the selected temperature,
when power resumes.
NOTE: The operation varies depending on the time length of power failure and other conditions.
(See SECTION E : OPERATION)
5. Fully Vented System
GB
Flue Pipe system uses outside air for combustion and vents all combustion products to outdoors.
1
FF-95
92.4% (1)
High - 9.50 kW (32,400 BTU/h)
Med - 5.49 kW (18,700 BTU/h)
Low - 2.96 kW (10,100 BTU/h)
High - 1.07 L/h
Med - 0.620 L/h
Low - 0.334 L/h
External tank (2)
Paraffin
760 × 700 × 427 mm
34 kg
70 ~ 80 mm diameter
3 m, 3 bends or less (See SECTION I: INSTALLATION)
230 Volts AC, 50 Hz
(220 Volts AC, 50/60 Hz) (3)
Preheat - MAX 280 W
Burning - MAX 52 W
2.400GHz to 2.4835GHz (4)
IEEE 802.11n/g/b (4)
SAFETY FEATURES
Heat shield plate
Circulation fan
Heat chamber
Peep hole
Flame sensor
Burner ring
Igniter
Burner
Adjustable leg
ENGLISH
Overheat protector
Heat exchanger
Blower motor
Fuel pipe
Fuel pump
Red float release button
Fuel sump
Fuel strainer (inside)
Drip tray