7. Loosen the clamping ring (Pos. 6) that connects the filter component
(Pos. 2) with the transport adapter (Pos. 5). Lift the filter unit (item 2) by
the transport lugs (item 7).
Fig. 28: Connecting the filter component to the fan component
8. Place the filter component (Pos. 2) on the fan component (Pos. 3) that is
anchored to the floor and fix it in place with the clamping ring (Pos. 6).
Please ensure the proper fit of the seal in the clamping ring (Pos. 6).
Fig. 29: Connecting the extraction component with the filter component
1502828-04