not damaged and that the dust collection container (Pos. 1) is noticeably
held by the magnet holder (Pos. 2).
7. Connect the product to the power supply and press the on/off switch to
put it back into operation. See also the chapter Commissioning.
7.2.2 Draining the condensate from the compressed air vessel
According to use, but at least once a month, the condensate that forms
must be drained from the compressed air containers.
Fig. 36: Draining the condensate from the compressed air vessel
To do so, proceed as follows:
1. Hold a cup or another suitable vessel under the needle valve (Pos. 1)
outlet opening and open the valve slowly with the other hand.
2. Only close the valve again when just air is escaping.
7.2.3 Visual inspection of the product
A visual inspection of the product must be carried out quarterly.
To do so, proceed as follows:
Check the product for signs of damage.
A qualified electrician must check all connection cables for damage.
Check compressed air connections and hoses for visible damage and
leaks.