Resistance; Continuity Test; Diode Test; Capacitance - Egatronic 51253 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

E. Resistance
Range
Resolution
200
2k
0.0001k
20k
0.001k
200k
0.01k
2M
0.0001M
20M
0.001M
F. Continuity Test
Range
Resolution
Remarks:
- Open circuit voltage approximate -1.2V.
- The buzzer does not sound when the test resistance is >60 .
- The beeper comes on continuously for open conditions, that is test resistance is ≤40 .
G. Diode Test
Range
Resolution
0.0001V
Remarks:
- Open circuit voltage approximate 2.8V.
- A good silicon junction drops between 0.5V and 0.8V.
H. Capacitance
Range
Resolution
20nF
0.001nF
200nF
0.01nF
2µF
0.0001µF
20µF
0.001µF
200µF
0.01µF
2mF
0.0001mF
20mF
0.001 mF
COD. 51253
±(0.5%+20)+
0.01
test leads open
circuit value
±(0.5%+20)
±(1%+20)
±(1%+40)
±(1.5%+40)
0.01
COD. 51253
±(1.5%+20)+

capacitance

value of open
circuit test
leads
±(1.5%+20)
±(1.5%+40)
±(5%+40)
Not specified
Accuracy
COD. 51254
±(0.4%+20)+
test leads open
circuit value
±(0.4%+20)
±(0.8%+20)
±(1%+40)
±(1.5%+40)
Overload Protection
1000V
Overload Protection
1000V
Accuracy
COD. 51254
±(1.2%+20)+
capacitance
value of open
circuit test
leads
±(1.2%+20)
±(1.2%+40)
±(1.5%+40)
±(5%+40)
Not specified
Overload Protection
1000V
Overload Protection
1000V