5.3.3 Testing the feeder parallelism

C
In order to know if the feeder is parallel with the table it
would be enough to check that the index A is marking the
same panel thickness than the counter F (Fig. 26).
I.e. for a panel of 19 mm the counter F will show 00190 and
F
the index must mark also 19. If both indications are different
see the point 8.3 THE BOARD DOES NOT SLIDE.
B
A
(Figure 26)
EB140 / Operating instructions - 91