6. MACHINE OPERATION

6.1 CONTROL PANEL FUNCTIONS

(Figure 31)
A - Main switch closed with a padlock (MAINS ISOLATOR)
The machine's electrical supply is connected in position (I)
and disconnected in position (O).
Approximately 20 minutes are needed from start-up to the
time you are able to band edges with the machine, depending
on the room temperature.
B - Emergency pushbutton
Pushing the emergency switch B deactivates all the electri-
cal elements on the machine. To reset the pushbutton to its
initial position (reactivate it), turn the button clockwise and
release it.
EB140 / Operating instructions - 97