Errors and possible rectification

Position of the side arms
Position of the heating elements
76
You can perform the rectification measures listed below yourself, making sure
you follow the safety instructions.
The following appears in the display f:
<Error> <Appliance faulty> <Errorcode __>:
Errorcode 10
1. Error in temperature mea-
Errorcode 21 ... 25
2. Heating circuit inter-
Errorcode 31 ... 38
3. Fault in internal power
Errorcode 39
4. Internal communication
Errorcode 40 ... 49
5. Internal data error
The following appears in the display f:
<Error> <Appliance faulty switch off immediately> <Errorcode __>:
Errorcode 30
Heating cannot be switched
off.
Treatment temperature is too low:
Protection filter soiled
Protection filter in front of
the temperature sensor 3 is
soiled.
<Error> <Please check the position of the side arms>:
The side arms are in the
wrong position for the
selected treatment.
<Error> <Please check the position of the heating elements>:
The heating elements 1 are
in the wrong position for the
selected treatment.
Should further errors or malfunctions occur or the rectification measures listed
fail to eliminate the error, write down the error messages displayed and contact
the Wella Customer Service Centre.
For your own safety, do not try to correct other problems yourself!
➥ Switch off appliance and attach a FAULTY sign to
suring circuit.
➥ Switch off appliance and attach a FAULTY sign to
rupted.
➥ Switch off appliance and attach a FAULTY sign to
supply
➥ Switch off appliance and attach a FAULTY sign to
error
➥ Switch off appliance and attach a FAULTY sign to
➥ Switch off appliance immediately.
➥ Attach a FAULTY sign to the appliance.
➥ Replace protection filter as described in "section
➥ Turn the side arms in the direction of the arrow
➥ Turn the heating elements 1 in the direction of
it.
Contact Wella Customer Service.
it.
Contact Wella Customer Service.
it.
Contact Wella Customer Service.
it.
Contact Wella Customer Service.
it.
Contact Wella Customer Service.
Remove plug b.
Contact Wella Customer Service.
8.2" page 75.
shown in the display f.
the arrow shown in the display f.